OPERATION INSTRUCTIONS
To check for a leak:
1. Make 2-3 oz. leak check solution (one part
liquid dishwashing detergent and three parts
water).
2. Apply several drops of solution where
regulator connects to cylinder and to all hose
and valve connections
3. Make sure all patio heater and light valves
are OFF.
4. Turn cylinder valve ON.
If bubbles appear at any connection, there is a
leak.
1. Turn cylinder valve OFF.
2. If leak is at regulator/cylinder valve connection:
Disconnect, reconnect, and perform another
leak check. Apply the soapy solution to all hose and
valve connections. If you continue to see bubbles
after several attempts, cylinder valve is defective
and should be returned to cylinder’s place of
purchase.
3. If leak is at hose/regulator connection:
This part is defective and you should contact the
customer service department for replacement.
If NO bubbles appear at any connection, the connections are secure.
NOTE: Whenever gas connections are loosened or removed, you must perform a complete leak test.
• Perform all leak tests outdoors.
• Extinguish all open flames.
• NEVER leak test when smoking.
• Do not use the heater until all connections have been
leak tested and do not leak.
Regulator / Cylinder
connection