21. RELIABILITY TESTS
The measurement should be done after being exposed to room temperature and humidity for
1 hour.
No. Item Limit Condition
1
Heat-shock-
restance test
Electrical parameter
should be in specification
Temperature:125°C to -50°C
Voltage: off
Period: 500cycles
Temp. Cycle: -50°C and +125°C each
7min.
2
Humidity load life
test
the same as above
Temprerature: +85°C
Humidity: 85%
Period: 500hrs
Voltage: on
3 Vibration test the same as above
Vibration Ampl.: 1.5mm
Vibr. Freq.: 10~55~10Hz (total 1min.)
Directions: X; Y; Z each 1hrs
4 ESD test the same as above
Regarding JEDEC JESD-22a114D each
contact with 100pF, 1.5kOhm min. 2kV
(Human Body Model HBM)
5 MSL test the same as above
Pre conditioning:
Temperature: +85°V
Humidity: 85°C
Period: 96hrs
Soldering condition:
Peak: 260°C for ~10s
2 times
22. CAUTIONS
Failure to do so may result in degrading of the product’s functions and damage to the
product.
22.1. DESIGN NOTES
(1) Please follow the conditions written in this specification, especially the control
signals of this module.
(2) The supply voltage has to be free of AC ripple voltage (for example from a
battery or a low noise regulator output). For noisy supply voltages, provide a
decoupling circuit (for example a ferrite in series connection and a blocking
capacitor to ground of at least 47uF directly at the module).
(3) This product should not be mechanically stressed when installed.
(4) Heat is the major cause of shortening the life of these products. Please keep
this product away from heat.