User's Manual
Table Of Contents
- KEY FEATURES
- APPLICATIONS FOR THE MODULE
- DESCRIPTION OF THE MODULE
- SCOPE OF THIS DOCUMENT
- HISTORY FOR THIS DOCUMENT
- TERMINAL LAYOUT
- BLOCK DIAGRAM
- KEY PARTS LIST
- TEST CONDITIONS
- ABSOLUTE MAXIMUM RATINGS
- OPERATING CONDITIONS
- DC ELECTRICAL CHARACTERISTICS
- A/D CONVERTER CHARACTERISTICS
- AC ELECTRICAL CHARACTERISTICS
- MECHANICAL REQUIREMENTS
- SOLDERING TEMPERATURE-TIME PROFILE (FOR REFLOW SOLDERING)
- MODULE DIMENSIONS
- FOOT PRINT OF THE MODULE
- LABELING DRAWING
- RECOMMENDED LAND PATTERN
- SOFTWARE
- RELIABILITY TESTS
- APPLICATION NOTES
- PACKAGING
- ORDERING INFORMATION
- ROHS DECLARATION
- DATA SHEET STATUS
- REGULATORY INFORMATION
- RELATED DOCUMENTS
- GENERAL INFORMATION
- LIFE SUPPORT POLICY
CLASSIFICATION
Einstufung
PRODUCT SPECIFICATION
Produktspezifikation
No.
DS-ETR2-2400-102
REV.
D
SUBJECT
Thema
MODEM FOR IEEE802.15.4 (ZIGBEE)
“ZigBee” Modem“ (IEEE802.15.4)
PAGE
Seite
20 of 29
CUSTOMER’S CODE
ETRX2
PANASONIC’S CODE
ENWC9A0xyzE
DATE
Datum
01.08.2006
HIGH FREQUENCY PRODUCTS DIVISION
Module Business
PANASONIC ELECTRONIC DEVICES
(EUROPE) GmbH
APPROVED
genehmigt
CHECKED
geprüft
DESIGNED
erstellt
21.3. EMBER ZIGBEE
TM
STACK
EmberZNet (currently version 2.3) is the ZigBee stack provided with EM250. It supports as
networking topologies true mesh, star and cluster networks. The ZigBee devices ZigBee
Coordinator, ZigBee Full Fuctional Device and ZigBee End Devices are supported.
For the ease of application programming EmberZNet is controlled by the application over
API commands. Direct ZigBee APS layer APIs are provided for applications that require
low level ZigBee control.
According to [1] each ZigBee device has a unique address. This address is provided
by Ember Inc. with the EM250.
For more information on the items above see the website of Ember Inc. (www.ember.com)
and the documentation included in the Ember Insight Desktop package as part of the
Ember development kits.
22. RELIABILITY TESTS
Zuverlässigkeitstests
The measurement should be done after exposed to room temperature and humidity for 1hour.
Die Messungen sollten erst nach einer Stunde Lagerung unter normalen Bedingungen erfolgen.
No.
Item
Punkt
Limit
Grenzwerte
Condition
Bedingung
1 Vibration test
Electrical parameter should be
in specification
a) Freq.:10~50Hz,Amplitude:1.5mm
a) 20min. / cycle,1hrs. each of XYZ axis
b) Freq.:30~100Hz, 6G
b) 20min. / cycle,1hrs. each of XYZ axis
2 Shock test the same as the above
Dropped onto hard wood from height of 50cm for
3 times
3 Heat cycle test the same as the above
-40°C for 30min. and +85°C for 30min.;
each temperature 300 cycles
4 Moisture test the same as the above +60°C, 90% RH, 300h
5 Low temp. test the same as the above -40°C, 300h
6 High temp. test the same as the above +85°C, 300h
23. APPLICATION NOTES
Applikationshinweise
23.1. CAUTIONS FOR SAFETY
Sicherheitshinweise
These specifications are intended to preserve the quality assurance of products as
individual components.
Before use, check and evaluate their operation when mounted on your products. Abide by
these specifications, without deviation when using the products.These products may short-
circuit. If electrical shocks, smoke, fire, and/or accidents involving human life are