Description
Ventilating fan shall be Low Noise ceiling mount
type rated for continuous run. Fan shall be
ENERGY STAR
®
rated and certified by the
Home Ventilating Institute (HVI). Evaluated by
Underwriters Laboratories and conform to both UL
and cUL safety standards.
Motor/Blower:
• Four–pole totally enclosed condenser motor
rated for continuous operation.
• Power Rating shall be 120 volts and 60 Hz.
• Fan shall be UL listed for tub/shower enclosure
when used with a GFCI branch circuit wiring.
• Motor equipped with thermal–cutoff fuse.
• Removable with permanently lubricated plug–in
motor.
Housing:
• Rust proof paint, galvanized steel body.
• 6" diameter duct adaptor.
• Built in backdraft damper.
• Expandable extension bracket up to 26".
Grille:
• Attractive design using PP material.
• Attaches directly to housing with torsion springs.
Warranty:
• ALL Parts: For period of 3 years from the date
of the original purchase.
Architectural Specifications:
Ventilating fan shall be of the ceiling mount,
ENERGY STAR rated type, with no less than 190
CFM and no more than 0.8 sone as certied by
the Home Ventilating Institute (HVI) at 0.1 static
pressure in inches water gauge(w.g.) and with
no less than 144 CFM no more than 1.4 sone as
certied by HVI at 0.25 w.g. Power Consumption
shall be no greater than 42 watts at 0.1 w.g. and
42 watts at 0.25 w.g. ENERGY STAR rated with
efciency of no less than 4.5 CFM/watt at 0.1
w.g. and 3.4 CFM/watt at 0.25 w.g. The motor
shall be totally enclosed, four pole condenser type
engineered to operate continuously. Power rating
shall be120v/60Hz. Duct diameter shall be no less
than 6". Fan shall be UL and cUL listed for tub/
shower enclosure when used with GFCI branch
circuit wiring. Fan shall be ASHRAE 62.2, LEED,
ENERGY STAR IAP, EarthCraft, California Title-24,
and WA Ventilation Code compliant.
FV-20VQ3
Panasonic Home and Environment Company
Division of Panasonic Corporation of North America
One Panasonic Way
Secaucus, NJ 07094
www.panasonic.com/building
Specications: WhisperCeiling FV-20VQ3
6" Duct
Static Pressure in inches w.g.
0.1 0.25
Air Volume (CFM)
190 144
Noise (sones)
0.8 1.4
Power Consumption (watts)
42 42
Energy Efficiency (CFM/Watt)
4.5 3.4
Speed (RPM)
696 871
Current (amps)
0.35 0.35
ENERGY STAR rated
YES
Washington State VIAQ Code
YES
As of date 4/11
For complete Installation Instructions visit www.panasonic.com/building
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
FV-20VQ3
6" duct
VF11076SS-20
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
050 100 150 200
Airflow(CFM)
FV-20VQ3
20 Feet
40 Feet
60 Feet
80 Feet
100 Feet
Static Pressure(inch w.g.)