Datasheet

GQ (AGQ)
1
en_ds_61008_0000: 100805J
SPECIFICATIONS
ULTRA-SMALL PACKAGE
FLAT POLARIZED RELAY
GQ RELAYS
(AGQ)
TESTING
7.20–0.3
.283–.012
10.60–0.3
.417–.012
5.20–0.2
.205–.008
10.60–0.3
.417–.012
Max.5.40
.213
7.20–0.3
.283–.012
mm inch
FEATURES
• Compact flat body saves space
With a small footprint of 10.6 mm (L) ×
7.2 mm (W) .417 inch (L) × .283 inch (W)
for space savings, it also has a very short
height of 5.2 mm .205 inch. (Standard PC
board type.)
• Outstanding surge resistance.
Surge withstand between open contacts:
1,500 V 10×160 µs (FCC part 68)
Surge withstand between contacts and
coil: 2,500 V 2×10 µs (Telcordia)
• The use of twin crossbar contacts
ensures high contact reliability.
AgPd contact is used because of its good
sulfide resistance. Adopting low-gas
molding material. Coil assembly molding
technology which avoids generating
volatile gas from coil.
• Increased packaging density
Due to highly efficient magnetic circuit
design, leakage flux is reduced and
changes in electrical characteristics fro
m
components being mounted close-
together are minimized. This all means
a
packaging density higher than ever
before.
• Nominal operating power: 140 mW
• Outstanding vibration and shock
resistance.
Functional shock resistance:
750 m/s
2
{75G}
Destructive shock resistance:
1,000 m/s
2
{100G}
Functional vibration resistance:
10 to 55 Hz (at double amplitude of 3.3
mm .130 inch)
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of 5 m
m
.197 inch)
Contact
Remarks:
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
Detection current: 10mA.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*
5
Half-wave pulse of sine wave: 6 ms;detection time: 10µs.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10µs.
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (see catalog).
Characteristics
Notes:
I1 This value can change due to the switching frequency, environmental
conditions, and desired reliability level, therefore it is recommended to check this
with the actual load.
I2 The upper limit for the ambient temperature is the maximum temperature that
can satisfy the coil temperature rise. Under the packing condition, allowable
temperature range is from –40 to +70°C –40° to +158°F.
Arrangement 2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1A )
100 m
Contact material
Stationary: AgPd+Au clad
Movable: AgPd
Rating
Nominal switching capacity
(resistive load)
1 A 30 V DC
0.3 A 125 V AC
Max. switching power
(resistive load)
30 W, 37.5 V A
Max. switching voltage 110 V DC, 125 V AC
Max. switching current 1 A
Min. switching capacity I1 10 µA 10 mV DC
Nominal
operating
power
Single side stable
140mW (1.5 to 12 V DC)
230mW (24 V DC)
1 coil latching
100mW (1.5 to 12 V DC)
120mW (24 V DC)
Expected
life (min.
operations)
Mechanical (at 180 cpm) 5 × 10
7
Electrical
(at 20 cpm)
1 A 30 V DC
resistive
10
5
0.3 A 125 V
AC resistive
10
5
Initial insulation resistance*
1
Min. 1,000M (at 500V DC)
Initial
breakdown
voltage*
2
Between open contacts 750 Vrms for 1min.
Between contact sets 1,000 Vrms for 1min.
Between contacts and coil 1,500 Vrms for 1min.
Initial surge
voltage
Between open contacts
(10×160 µs)
1,500 V(FCC Part 68)
Between contacts and coil
(2×10 µs)
2,500 V(Telcordia)
Operate time [Set time]*
3
(at 20°C)
Max. 4 ms (Approx. 2 ms)
[Max. 4 ms (Approx. 2 ms)]
Release time (without diode)
[Reset time]*
3
(at 20°C)
Max. 4 ms (Approx. 1 ms)
[Max. 4 ms (Approx. 2 ms)]
Temperature rise*
4
(at 20°C) Max. 50°C
Shock resistance
Functional*
5
Min. 750 m/s
2
{75G]
Destructive*
6
Min. 1,000 m/s
2
{100G]
Vibration resistance
Functional*
7
10 to 55 Hz at double
amplitude of 3.3 mm
Destructive
10 to 55 Hz at double
amplitude of 5 mm
Conditions for
operation, transport
and storage*
8
(Not freezing and
condensing at low
temperature)
Ambient
temperature I2
–40°C to 85°C
–40°F to 185°F
Humidity 5 to 85% R.H.
Unit weight Approx. 1 g .035 oz

Summary of content (4 pages)