Alarm Recording (Emergency Recording)
When an emergency occurs at the monitoring site during prolonged monitoring and recording, the alarm function
is automatically triggered, and alarm recording is performed.
Principle of Alarm Recording Connecting the Alarm Input
Connector
Alarm recording starts when the alarm switch is set
on. When the alarm reset switch is set ON after
recording has started, alarm recording is released
and operation is returned to the original time lapse
recording mode.
Alarm recording can be released by pressing the
STOP button during alarm recording.
However, it cannot be released even by pressing the
STOP button if the MENU/REC LOCK switch is at
REC LOCK or INT is lit on the display.
Alarm recording can be automatically reset without
supplying the alarm reset input signal.
The reset time can be set for 30 sec., 1.0, 2.0, 3.0,
5.0 or 10 minutes.
Another option is alarm recording only while the alarm
input signal is supplied.
Alarm recording is also possible as far as the end
of the tape.
Alarm and Display Methods during
Alarm Recording
When an alarm signal is supplied by an alarm sensor
(door or intercom switch, etc.) during recording in a
time lapse mode, the recording speed is switched to
the 3- or 6-hour mode and the details of the state of
emergency are faithfully recorded.
ALARM display lamp
When an alarm signal is supplied, the alarm display
lamp functions as follows.
Alarm input Alarm reset input
Time lapse mode Alarm mode
(3H/6H)
Time lapse mode
Tape end
Tape start
Recording Alarm recording Recording
“A” display
appears
17-11-00 3H
10:14:30 A
Alarm
lamp
Alarm input Alarm reset
input
switch is
pressed twice.
OffFlashingOn
Display
switch to
“3H” or “6H”.
TV monitor
Alarm reset switch
Alarm switch
Alarm switch
4 V – 14 V
TRACKING /
V-LOCK RESET
PULL OPEN
COUNTER /
REC
ALARM
TIME MODE
SEARCH
EJECT
REC REVIEW
REC
CAMERA
IN
OUT
TAPE END OUT
WARNING/
REC OUT
REC IN
COMMON
ALARM RESET IN
ALARM IN
AUDIO
SW OUT
AC IN
REV
FWD