User manual

4.2.2 RS232C Connection with PLC Tool Port
Connecting with 5 V DC type
Usable models
PLC
PLC communication cable
Programmable display
FP-X
FPΣ
FP0/FP0R
FP-e
FP2/FP2SH
Mini-DIN 5-pin
loose-wire cable
AIGT8142 5 V DC type RS232C type
Connecting to the TOOL port
Note: Connecting to the COM port is not available.
- Keep the cable no longer than 3 m.
- In case of connecting to PLC with all expansion slots used, prepare an external 5 V DC power supply
for the GT01 due to current consumption limits.
- When using the FP2/FP2SH, check whether or not the power can be supplied from the TOOL port
according to the calculation method of the number of expansion units described in the hardware
manual.
4-5