6. Setup
6.1 Main setting mode
To go to the main setting mode, press the key in the PV/SV display mode.
Set each setting item with the or key, and register the value with the key.
In the main setting mode, indicated setting items are different depending on the instrument status.
• Fixed value control
Setting items SV1 and SV2 will be indicated.
• Program control
Step SV and step time from Step 1 to Step 9 will be indicated.
This program pattern shows that the
temperature rises to 200
for 1 hour
and stays at 200 for 2 hours.
In this case,
Step 1 SV: 200
Step 1 time (1 hour): 01:00
Step 2 SV: 200
Step 2 time (2 hours): 02:00
Display
Item, Function, Setting range Default value
SV1 (step 1 SV) setting 0
• Sets SV1 or step 1 SV.
• Scaling low limit value to Scaling high limit value
Step 1 time setting 00:00
• Sets step 1 time.
Available only when program control function is selected during
OUT/OFF key function selection
• Setting range: 00:00 to 99:59
SV2 (step 2 SV) setting 0
• Sets SV2 or step 2 SV.
Available when SV1/SV2 external selection function is
selected during DI (digital input) function selection or when
program control function is selected during OUT/OFF key
function selection.
• Scaling low limit value to Scaling high limit value
Step 2 time setting 00:00
• Sets step 2 time.
Available only when program control function is selected during
OUT/OFF key function selection
• Setting range: 00:00 to 99:59
Step 3 SV setting 0
• Sets step 3 SV.
Available only when program control function is selected during
OUT/OFF key function selection
• Scaling low limit value to Scaling high limit value
Step 3 time setting 00:00
• Sets step 3 time.
Available only when program control function is selected during
OUT/OFF key function selection
• Setting range: 00:00 to 99:59
Step 4 SV setting 0
• Sets step 4 SV.
Available only when program control function is selected during
OUT/OFF key function selection
• Scaling low limit value to Scaling high limit value
Step number
12
200
0
1:00 2:00
C
C
Program control run
(Fig.6.1-1)