Operating Instructions Air Conditioner CS-C12PKF-3 CS-C18PKF-3 CS-C24PKF-3 Outdoor Unit CU-C12PKF-3 CU-C18PKF-3 CU-C24PKF-3 Operating Instructions Air Conditioner Thank you for purchasing Panasonic Air Conditioner. Installation instructions attached. Before operating the unit, read these operating instructions thoroughly and keep them for future reference. F568979 English Model No.
Provide electricity protection solution, maximum comfort, clean air and optimise energy saving ECONAVI and AUTO COMFORT Equipped with the human activity sensor, the air conditioner ensures to deliver cool air to you, and keeps the room consistently comfortable with minimum energy consumption. Furthermore, the sunlight sensor detects the sunlight intensity and helps control cooling temperatures to provide optimum comfort. See “To learn more...” for details.
Quick guide Table of contents Inserting the batteries 1 2 3 1 Pull out the back cover of remote control 2 Insert AAA or R03 batteries (can be used ~ 1 year) 3 Close the cover 2 1 2 OFF 1 SET 3 3 3 Confirm Accessories RESET 1 Select the desired mode AUTO FAN SPEED AIR SWING 2 ECONAVI 3 MODE 1 OFF/ON NANOE-G POWERFUL/ AIR SWING QUIET FAN SPEED 1 SET 2 OFF SET 3 CANCEL CLOCK • Remote control • AAA or R03 batteries × 2 • Remote control holder • Screws for remote control holder × 2
Safety precautions To prevent personal injury, injury to others or property damage, please comply with the following: Incorrect operation due to failure to follow instructions below may cause harm or damage, the seriousness of which is classified as below: WARNING This sign warns of death or serious injury. CAUTION This sign warns of injury or damage to property. The instructions to be followed are classified by the following symbols: This symbol denotes an action that is PROHIBITED.
Air Conditioner ◄ Complete wire without joining OR ◄ Approved connecting means (for example: approved socket and plug) Indoor Unit Complete wire without ◄ joining Outdoor Unit If the supply cord is damaged, it must be replaced by the manufacturer, service agent or similarly qualified persons in order to avoid a hazard. It is strongly recommended to be installed with Earth Leakage Circuit Breaker (ELCB) or Residual Current Device (RCD) to prevent electric shock or fire.
How to use ECONAVI To optimise energy saving ECONAVI MODE To select operation mode AUTO - For your convenience • Unit selects the operation mode according to the room temperature. • Once AUTO mode is selected, the unit will operate at the standard setting temperature.
See "To learn more..." for details. AUTO COMFORT To maximise comfort To set the timer To turn ON or OFF the unit at a preset time. AUTO COMFORT NANOE-G 1 To purify the air NANOE-G 1 • nanoe-G starts automatically when the unit is turned on with OFF/ON . • Can be activated even when the unit is turned off. In this condition, the unit will operate as a fan with AUTO fan speed and louver swing.
To learn more... Operation mode COOL: Use curtains to screen off sunlight and outdoor heat to reduce power consumption during COOL mode. DRY : Unit operates at low fan speed to give a gentle cooling operation. nanoe-G in-filter deactivation Depending on the unit’s accumulated operation time, nanoe-G in-filter deactivation may activate only once a day after the unit turned off. To remove the moisture left in the internal parts, the fan will operate for 30 minutes with louver opened slightly.
The human activity sensor will also scan for area of heat source and movement in a room. Detection area Human activity indicator 120º 7m At left area At center / multiple area At right area The unit judges human activity area for a few seconds before indicator updates. Based on area activeness horizontal airflow direction louver will adjust either fix at predetermined position or swing left/right periodically.
Cleaning instructions To ensure optimal performance of the unit, cleaning has to be carried out at regular intervals. Please consult authorised dealer. • Switch off the power supply and unplug before cleaning. • Do not touch the aluminium fin, sharp parts may cause injury. • Do not use benzine, thinner or scouring powder. • Use only soap ( pH 7) or neutral household detergent. • Do not use water hotter than 40 °C.
Troubleshooting The following symptoms do not indicate malfunction. Symptom Cause Mist emerges from indoor unit. Water flowing sound during operation. The room has a peculiar odour. • Condensation effect due to cooling process. • Refrigerant flow inside the unit. • This may be due to damp smell emitted by the wall, carpet, furniture or clothing. Indoor fan stops occasionally during automatic • This helps to remove the surrounding odour. fan speed setting.
Information English Information for Users on Collection and Disposal of Old Equipment and used Batteries [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol.