Datasheet

YE Inverter models are powerful and efficient.
WALL MOUNTED YE TYPE
STANDARD INVERTER
Energy
saving
5,60 A+
SEER
SEASONAL ENERGY
EFFICIENCY RATIO
3,80 A
SCOP
SEASONAL COEFFICIENT
OF PERFORMANCE
SUPER QUIET
Silent air
22 dB
Kit KIT-YE9-QKE KIT-YE12-QKE
Indoor CS-YE9QKE CS-YE12QKE
Outdoor CU-YE9QKE CU-YE12QKE
Cooling capacity Nominal (Min - Max) kW 2,50 (0,85 - 3,00) 3,50 (0,85 - 3,90)
Nominal (Min - Max) kCal/h 2.150 (730 - 2.580) 3.010 (730 - 3.350)
SEER Nominal Energy Saving
5,60 h 5,60 h
Pdesign (cooling) 2,5 3,5
Power input cooling Nominal (Min - Max) kW 0,720 (0,250 - 1,020) 1,090 (0,255 - 1,280)
Annual electricity consumption (cooling)
1)
kWh/a 156 219
Heating capacity Nominal (Min - Max) kW 3,30 (0,80 - 4,10) 4,00 (0,80 - 5,10)
Nominal (Min - Max) kCal/h 2.840 (690 - 3.530) 3.440 (690 - 4.390)
Heating capacity at -7°C Nominal kW 2,66 3,2
SCOP Nominal Energy Saving
3,80 a 3,80 a
Pdesign at -10 °C kW 1,9 2,4
Power input heating Nominal (Min - Max) kW 0,860 (0,195 - 1,180) 1,100 (0,200 - 1,470)
Annual electricity consumption (heating)
1)
kWh/a 700 884
Indoor Unit
Power source V 230 230
Recommended fuse A 16 16
Recommended power cable section mm² 1,5 1,5
Connection indoor / outdoor mm² 4 x 1,5 4 x 1,5
Current (Nominal) Cooling / Heating A 3,20 / 3,80 4,8 / 4,90
Maximum current A 5,3 6,7
Air volume Cooling / Heating m³/h 702 / 768 738 / 768
Moisture removal volume l/h 1,5 2
Sound pressure level
2)
Cooling (Hi / Lo / Q-Lo) dB(A) 41 / 26 / 22 42 / 30 / 22
Heating (Hi / Lo / Q-Lo) dB(A) 41 / 27 / 25 42 / 33 / 25
Sound power level Cooling (Hi) dB 57 58
Heating (Hi) dB 57 58
Dimensions H x W x D mm 290 x 870 x 214 290 x 870 x 214
Net weight kg 9 9
Air purifier filter No No
Outdoor Unit
Air volume Cooling / Heating m³/h 1.926 / 1.872 1.860 / 1.860
Sound pressure level
2)
Cooling (Hi) dB(A) 47 48
Heating (Hi) dB(A) 48 50
Sound power level Cooling (Hi) dB 62 63
Heating (Hi) dB 63 65
Dimensions
3)
H x W x D mm 542 x 780 x 289 542 x 780 x 289
Net weight kg 31 33
Piping connections Liquid pipe inch (mm) 1/4 (6,35) 1/4 (6,35)
Gas pipe inch (mm) 3/8 (9,52) 3/8 (9,52)
Refrigerant loading R410A kg 0,85 1,00
Elevation difference (in/out)
4)
Max m 15 15
Piping length Min / Max m 3 / 15 3 / 15
Precharge length Max m 7,5 7,5
Additional gas g/m 20 20
Operating range Cooling Min / Max °C 5 / +43 5 / +43
Heating Min / Max °C -10 / +24 -10 / +24
Rating Conditions: Cooling Indoor 27°C DB / 19°C WB. Cooling Outdoor 35°C DB / 24°C WB. Heating Indoor 20°C DB. Heating Outdoor 7°C DB / 6°C WB. (DB: Dry Bulb; WB: Wet Bulb)
Connectivity restriction: JKE units are not compatible with QKE units.
1) The annual energy consumption is calculated in accordance with the ErP directive. 2) The Sound pressure level of the units shows the value measured of a position 1 meter in front of the main body and 0,8 m below the unit. The sound pressure is measured in
accordance with Eurovent 6/C/006-97 specification. Q-Lo: The lowest fan speed. Lo: The second lowest fan speed. 3) Add 70 mm for piping port. 4) When installing the outdoor unit at a higher position than the indoor unit.
Specifications subject to change without notice.
For detailed information about ErP, please visit our page http://www.ptc.panasonic.eu
Possible
to use on
R22 pipings
R22 RENEWAL
5 year
compressor
warranty