Manual

ENGLISH
5
NOTES
NOTES
PATR
O
L/
,
Q
UIET
,
P
O
WERFUL
,
ECO
PATROL
Can be activated in all modes and can be cancelled
by pressing the respective button again.
Q
UIET
,
P
O
WERFUL
,
ECO
PATROL
Can not be selected at the same time.
Can not be activated during “MILD DRY COOLING”
operation is activated.
TO SET THE TIMER
TO SET THE TIMER
2 sets of ON and OFF timers are available to turn ON
or OFF the unit at different preset time.
Complete below procedures to set each timer:
ON
OFF
1
Cancel
Cancel
2
ET
Select ON or OFF timer
Set the
time
Con rm
Example of application at living room:
Morning: ON
at 07:00 (Wake up)
OFF
at 08:00 (Out for work)
Evening: ON
at 17:00 (Back home)
OFF at 22:00 (Sleep)
To cancel ON or OFF timer, press
O
N
or
OFF
to
select respective or then press
CANCEL
.
If timer is cancelled manually or due to power failure,
you can restore the timer again by pressing
O
N
or
OFF
to select respective or then press
SET
.
Upcoming timer will be displayed and will be activated
in sequence.
When ON Timer is set, the unit may start earlier (up
to 30 minutes) before the actual set time in order to
achieve the desired temperature on time.
Timer operation is based on the clock set in the
remote control and repeats daily once set. For clock
setting, please refer to Remote Control Preparation at
back cover.
7
TO ENJOY CLEAN & FRESH AIR
PATROL/
PATROL
NORMAL
PATROL - To monitor air quality
Detects air quality; e-ion operation activates when air
quality is at dirty level.
Can be activated even when the unit is turned off.
Patrol starts automatically with the unit switched on with
OFF/ON
.
- To freshen and purify the air
Generates negative ions to produce fresh air effect and
attract dust which will then be captured at the positively
charged e-ion lters.
Can be activated even when the unit is turned off. In this
condition, fan speed and air swing can not be adjusted.
8
TO IMPROVE HUMIDITY AND MOISTURE LEVEL
This operation reduces air dryness and provides you with
a comfortable living environment during COOL mode only.
When vertical air ow direction is set to AUTO, it stops at
lower position to avoid cold air contact. However, you can
adjust the louver direction manually.
9
TO ENJOY QUIET
ENVIRONMENT
This operation reduces air ow noise.
10
TO ACHIEVE TEMPERATURE
QUICKLY
This operation will stop automatically after 20 minutes.
11
Press and hold for 5 seconds to dim or restore the
unit’s indicator brightness.
12
Press and hold for approximately 10 seconds to
show temperature setting in °C or °F.
13
Press to restore the remote control’s default setting.
14
Not used in normal operations.