Operation mode
It is possible to operate the indoor units individually or simultaneously. The priority of
operation is placed on the first unit that turned on.
During operation, HEAT and COOL modes cannot activate at the same time for different
indoor units.
The power indicator blinks to indicate the indoor unit is standing by for different operation
mode.
AUTO : During operation, the POWER indicator will blinks at initial.
Single
Unit selects operation mode every 10 minutes according to the setting and room
temperatures.
Multi
Unit selects operation mode every 3 hours according to setting temperature,
outdoor temperature and room temperature.
HEAT : The POWER indicator blinks at the initial stage of this operation. Unit takes a while
to warm up.
For system which HEAT mode has been locked, if operation mode other than
HEAT is selected, the indoor unit stops and the POWER indicator blinks.
COOL : Provides ef cient comfort cooling to suit your needs.
DRY : Unit operates at low fan speed to give a gentle cooling operation.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
HEAT : 20.0 °C ~ 24.0 °C /
68 °F ~ 75 °F.
COOL: 26.0 °C ~ 28.0 °C /
79 °F ~ 82 °F.
Air ow direction
In COOL/DRY mode:
If AUTO is set, the ap swings up/down automatically.
In HEAT mode:
If AUTO is set, the horizontal ap is xed at the predetermined position.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature °C (°F)
Indoor Single split outdoor unit *
1
Multi split outdoor unit *
2
DBT WBT DBT WBT DBT WBT
COOL
Max. 32 (89.6) 23 (73.4) 43 (109.4) 26 (78.8) 46 (114.8) 26 (78.8)
Min. 16 (60.8) 11 (51.8) -10 (14.0) - -10 (14.0) -
HEAT
Max. 30 (86.0) - 24 (75.2) 18 (64.4) 24 (75.2) 18 (64.4)
Min. 16 (60.8) - -15 (5.0) -16 (3.2) -15 (5.0) -16 (3.2)
DBT: Dry bulb temperature, WBT: Wet bulb temperature
*
1
CU-Z25UBEA, CU-Z35UBEA, CU-Z50UBEA, CU-Z60UBEA
*
2
CU-3E18PBE, CU-4E23PBE, CU-4E27PBE, CU-5E34PBE, CU-2E12SBE, CU-2E15SBE, CU-2E18SBE,
CU-3E23SBE, CU-2Z35TBE, CU-2Z41TBE, CU-2Z50TBE, CU-3Z52TBE, CU-3Z68TBE, CU-4Z68TBE,
CU-4Z80TBE, CU-5Z90TBE
To learn more...
Single
Single split system
Multi
Multi split system
ACXF55-17710_book1.indb 18ACXF55-17710_book1.indb 18 12/14/2017 3:59:39 PM12/14/2017 3:59:39 PM