Operating Instructions
20
Cleaning instructions
To ensure optimal performance of the unit,
cleaning has to be carried out at regular
intervals. Dirty unit may caused malfunction
and you may retrieve error code “H 99”.
Please consult authorised dealer.
• Switch off the power supply and unplug before
cleaning.
• Do not touch the aluminium fi n, sharp parts
may cause injury.
• Do not use benzine, thinner or scouring
powder.
• Use only soap ( pH 7) or neutral household
detergent.
• Do not use water hotter than 40 °C / 104 °F.
Indoor unit
( Structure of the unit may vary
depending on the model)
AUTO
OFF/ON
Aluminium fi n
Front panel
Air fi lters
Air Purifying Filter
(
CS-TZ20/25/35/42/50WKEW,
CS-RZ20/25/35/50WKEW,
CS-MTZ16WKE)
Indoor unit
Wipe the unit gently with a soft,
dry cloth.
Coils and fans should be
cleaned periodically by
authorised dealer.
Outdoor unit
Clear debris that surround the
unit.
Clear any blockage from the
drain pipe.
Front panel
Wash gently and dry.
How to remove front panel
1
Raise over
horizontal
level.
2
Pull upward.
Horizontal
Close it securely
AUTO
OFF/ON
1
Hold
horizontally.
2
Match and push in.
3
Close down.
4
Press both ends and center of the front
panel.
Air Purifying Filter
Air Purifying Filter
( Fitting location may vary on
models.)
• Do not wash the air purifying fi lter.
• Replace any damaged fi lter.
CS-TZ20/25/35/42/50/60/71WKEW,
MTZ16WKE - Part no.: CZ-SA31P
(replace every 2 years).
CS-RZ20/25/35/50WKEW
- Part no.: CZ-SA32P
(replace every 10 years).
Air Purifying Filter
(CS-TZ60/71WKEW)
Air fi lters
Once every 2 weeks
• Wash/rinse the fi lters gently
with water to avoid damage to
the fi lter surface.
• Dry the fi lters thoroughly under shade,
away from fi re or direct sunlight.
• Replace any damaged fi lters.
Remove air fi lter Attach air fi lter
Insert into the unit
ACXF55-27151.indb 20ACXF55-27151.indb 20 12/2/2019 10:07:43 AM12/2/2019 10:07:43 AM