Datasheet

14
Type
Thru-beam Retrorefl ective
Long sensing range With polarizing fi lters
Model No.
Light-ON Dark-ON Light-ON Dark-ON Light-ON Dark-ON
NPN output CX-411A-C05 CX-411B-C05 CX-412A-C05 CX-412B-C05 CX-491A-C05-Y CX-491B-C05-Y
Item PNP output CX-411A-P-C05 CX-411B-P-C05 CX-412A-P-C05 CX-412B-P-C05
CX-491A-P-C05-Y CX-491B-P-C05-Y
Sensing range 10 m 32.808 ft 15 m 49.213 ft 3 m 9.843 ft (Note 2)
Sensing object ø12 mm ø0.472 in or more opaque object (Note 3)
ø50 mm
ø1.969 in or more transparent,
translucent or opaque object (Note 2, 4)
Hysteresis
Repeatability (perpendicular to sensing axis)
0.5 mm 0.020 in or less
Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption
Emitter: 15 mA or less
Receiver: 10 mA or less
Emitter: 20 mA or less
Receiver: 10 mA or less
13 mA or less
Output
<NPN output type>
NPN open-collector transistor
• Maximum sink current: 100 mA
Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 2 V or less (at 100 mA sink current)
1 V or less (at 16 mA sink current)
<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA
Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (at 100 mA source current)
1 V or less (at 16 mA source current)
Short-circuit protection
Incorporated
Response time 1 ms or less
Operation indicator Orange LED (lights up when the output is ON)(incorporated on the receiver for thru-beam type)
Stability indicator
Green LED (lights up under stable light received condition or stable dark condition)(incorporated on the receiver for thru-beam type)
Power indicator Green LED (lights up when the power is ON) (incorporated on the emitter)
Sensitivity adjuster
Automatic interference
prevention function
Two units of sensors can be mounted
close together with interference prevention
lters. (Sensing range: 5 m 16.404 ft)
Incorporated (Two units of sensors can
be mounted close together.)
Environmental resistance
Protection IP67 (IEC)
Ambient temperature -25 to +55 °C
-13 to +131 °F (No dew condensation or icing allowed), Storage: -30 to +70 °C -22 to +158 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance
Incandescent light: 3,000 x at the light-receiving face
V
oltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 M, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, 1.5 mm
0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each
Shock resistance
500 m/s
2
acceleration (50 G approx.) in X, Y and Z directions for three times each
Emitting element (modulated) Red LED Infrared LED Red LED
Peak emission wavelength
680 nm 0.027 mil 870 nm 0.034 mil 680 nm 0.027 mil
Material Enclosure: PBT (Polybutylene terephthalate), Lens: Acrylic, Indicator cover: Acrylic
Cable 0.2 mm
2
3-core (thru-beam type emitter: 2-core) cabtyre cable, 0.5 m 1.640 ft long
Cable extension Extension up to total 100 m
328.084 ft is possible with 0.3 mm
2
, or more, cable (thru-beam type: both emitter and receiver)
Weight
Net Emitter: 20 g approx., Receiver: 20 g approx. 20 g approx.
Gross 50 g approx. 30 g approx.
Notes: 1) Where measurement conditions have not been specifi ed precisely, the conditions used were an ambient temperature of +23 °C
+73.4 °F.
2)
The sensing range and the sensing object of the retroreflective type sensor are specifi
ed for the RF-230 refl ector (optional). The sensing range
represents the actual sensing range of the sensor. The sensing ranges itemized in “A” of the table below may vary depending on the shape of sensing
object. Be sure to check the operation with the actual sensing object.
Setting range
of the reflector: B
Sensing
object
Sensing
range: A
Sensor Reflector
(Optional)
CX-491
A
0 to 3 m
0 to 9.843 ft
B
0.1 to 3 m
0.328 to 9.843 ft
3) If slit masks (optional) are fi
tted, an object of ø0.5 mm ø0.020 in (using round slit mask) can be detected.
4) Make sure to confi rm detection with an actual sensor before use.
SPECIFICATIONS
Basic type
18/07/2011