Datasheet

FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PHOTO-
ELECTRIC
SENSORS
Selection
Guide
Amplifier
Built-in
EX-10
CX-400
EX-20
EX-30
EX-40
EQ-30
EQ-500
MQ-W
RX-LS200
RX
CY
PX-2
RT-610
Amplifier-
separated
Power Supply
Built-in
NX5
VF
SU-7 / SH
SS-A5 / SH
Other
Products
CX-400
Amplier
Built-in
Compact Photoelectric Sensor CX-400 SERIES
238
Designation
Model No.
Slit size
Sensing range Min. sensing object
Slit Sensor Slit on one side
Slit on both sides
Slit on one side
Slit on both sides
Round slit mask
For thru-beam
type sensor only
OS-CX-05
CX-411
ø0.5 mm
ø0.020 in
400 mm 15.748 in 20 mm 0.787 in
ø12 mm ø0.472 in ø0.5 mm ø0.020 in
CX-412□
600 mm 23.622 in 30 mm 1.181 in
OS-CX-1
CX-411
ø1 mm
ø0.039 in
900 mm 35.433 in 100 mm 3.937 in
ø12 mm ø0.472 in
ø1 mm ø0.039 in
CX-412□
1.35 m 4.429 ft 150 mm 5.906 in ø1.5 mm ø0.059 in
OS-CX-2
CX-411
ø2 mm
ø0.079 in
2 m 6.562 ft 400 mm 15.748 in
ø12 mm ø0.472 in
ø2 mm ø0.079 in
CX-412□
3 m 9.843 ft 600 mm 23.622 in ø3 mm ø0.118 in
Rectangular
slit mask
For thru-beam
type sensor only
OS-CX-05×6
CX-411
0.5 × 6 mm
0.020 × 0.236 in
2 m 6.562 ft 400 mm 15.748 in
ø12 mm ø0.472 in
0.5 × 6 mm
0.020 × 0.236 in
CX-412□
3 m 9.843 ft 600 mm 23.622 in
OS-CX-1×6
CX-411
1 × 6 mm
0.039 × 0.236 in
3 m 9.843 ft 1 m 3.281 ft
ø12 mm ø0.472 in
1 × 6 mm
0.039 × 0.236 in
CX-412□
4.5 m 14.764 ft 1.5 m 4.921 ft
OS-CX-2×6
CX-411
2 × 6 mm
0.079 × 0.236 in
5 m 16.404 ft 2 m 6.562 ft
ø12 mm ø0.472 in
2 × 6 mm
0.079 × 0.236 in
CX-412□
7.5 m 24.606 ft 3 m 9.843 ft
OPTIONS
Designation Model No. Sensing range Min. sensing object
Interference
prevention lter
For CX-441□
only
PF-CX4-V (Vertical)
2 pcs. per set
5 m 16.404 ft (Note 1)
ø12 mm ø0.472 in
(Note 1)
PF-CX4-H (Horizonal)
2 pcs. per set
5 m 16.404 ft (Note 1)
ø12 mm ø0.472 in
(Note 1)
Reector
For retroreective
type sensor only
RF-210
CX-491□
1 m 3.281 ft (Note 2)
ø30 mm ø1.181 in
CX-493□
1.5 m 4.921 ft (Note 2)
CX-481□
CX-482□
0.1 to 0.6 m
0.328 to 1.969 ft (Note 2)
RF-220
CX-491□
1.5 m 4.921 ft (Note 2)
ø35 mm ø1.378 in
CX-493□
3 m 9.843 ft (Note 2)
CX-481□
50 to 300 mm
1.969 to 11.811 in (Note 2)
CX-482□
0.1 to 1.3 m
0.328 to 4.265 ft (Note 2)
Round slit mask
OS-CX-□
Fitted on the front face of the sensor with
one-touch.
Rectangular slit mask
OS-CX-□×6
Fitted on the front face of the sensor with
one-touch.
Interference prevention lter
PF-CX4-V
PF-CX4-H
Two sets of CX-441□ can be mounted close
together.
Round slit mask
(Stainless steel)
Rectangular slit mask
(Stainless steel)
Reector
RF-210
RF-220
Interference prevention filter
33.3 mm
1.311 in
11 mm
0.433 in
12.8 mm
0.504 in
35.3 mm
1.390 in
8.3 mm
0.327 in
42.3 mm
1.665 in
Notes: 1) Value when attached to both sides.
2) Set the distance between the
CX-491□/493□ and the reector to 0.1 m 0.328 ft or more.
However, see the table below for
CX-48□.
The sensing range “A” may vary depending on the shape of sensing object.
Be sure to check the operation with the actual sensing object.
Setting range
of the reflector: B
Sensing
object
Sensing
range: A
Sensor Reflector
Model No.
A B
Sensor Reector
CX-481□ RF-220
50 to 300 mm
1.969 to 11.811 in
100 to 300 mm
3.937 to 11.811 in
CX-482□
RF-220
0.1 to 1.3 m
0.328 to 4.265 ft
0.5 to 1.3 m
1.640 to 4.265 ft
RF-210
0.1 to 0.6 m
0.328 to 1.969 ft
0.3 to 0.6 m
0.984 to 1.969 ft