Datasheet

DE (ADE)
1
en_ds_61101_0000: 310105D
SPECIFICATIONS
COMPACT HIGH-INSULATION
POLARIZED POWER RELAY
DE RELAYS
(ADE)
VDE
mm inch
12.5
.492
25.0
.984
12.5
.492
FEATURES
Conforms to VDE0631.
Insulating distance between coil and
contacts:
Clearance Min. 8mm .315 inch
Creepage distance Min. 8mm .315 inch
Extensive product line-up.
Surge voltage between contact and
coil 12 kV
Low operating power
Nominal operating power at 200 mW
(Single side stable, 2 coil latching)
Compact body saves space
Size: 12.5(W) × 25.0(L) × 12.5(H) mm
.492(W) × .984(L) × .492(H) inch
UL/CSA, VDE approved
Contact
Coil (at 20°C, 68°F)
Characteristics
Arrangement 1 Form A
1 Form A
1 Form B
2 Form A
Contact material Silver alloy
Initial contact resis-
tance, max. (By voltage
drop 6V DC 1A)
30m
Rating
(resistive
load)
Nominal
switching
capacity
10A 250V AC,
10A 30V DC
8A 250V AC,
8A 30V DC
8A 250V AC,
8A 30V DC
Max.
switching
power
2,500 VA*,
300W
2,000 VA*,
240W
2,000 VA*,
240W
Max.
switching
voltage
440V AC,
230V DC
440V AC,
230V DC
440V AC,
230V DC
Max.
switching
current
10A (16A)* 8A (16A)* 8A (16A)*
Min. switch-
ing capac-
ity
#1
100 mA, 5 V DC
Expected
life (min.
operations)
Mechanical
(at 300cpm)
10
7
Electrical
(at 20 cpm)
(resistive load)
10
5
10
5
(AC)
5 × 10
4
(DC)
Electrical
(
16A / 230 V
AC resistive)*
25000 20000
Nominal operating power
Single side stable 200 mW
1 coil latching 100 mW
2 coil latching 200 mW
Max. operating speed 20 cpm (at rated load)
Initial insulation resistance*
1
Min. 1,000 M
(at 500 V DC)
Initial
breakdown
voltage*
2
Between open contacts 1,000 Vrms
Between contact sets
4,000 Vrms (2 Form A,
1 Form A 1 Form B)
Between contact and coil 5,000 Vrms
Surge voltage between contact and coil*
3
Min. 12,000 V (initial)
Operate time [Set time]*
4
Max. 10ms (typ. 5ms)
[Max. 10ms (typ. 4ms)]
(at 20°C 68°F)
Release time (without diode) [Reset time]*
4
Max. 5ms (typ. 2ms)
[Max. 10ms (typ. 4ms)]
(at 20°C 68°F)
Temperature rise (at 70°C)*
5
Max. 50°C
Shock resistance
Functional*
6
Min. 196 m/s
2
{20 G}
Destructive*
7
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
8
10 to 55 Hz at double
amplitude of 2 mm
Destructive
10 to 55 Hz at double
amplitude of 3 mm
Conditions for operation,
transport and storage*
9
(Not freezing and condens-
ing at low temperature)
Ambient temp.
–40°C to 70°C
–40°F to 158°F
Humidity 5 to 85% R.H.
Unit weight Approx. 7 g .25 oz
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
Remarks
* 16A possible for one contact set only with max. 4000 VA switching power.
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*
4
Nominal operating voltage applied to the coil, excluding contact bounce time.
*
5
By resistive method
*
6
Half-wave pulse of sine wave: 11ms, detection time: 10ms.
*
7
Half-wave pulse of sine wave: 6ms
*
8
Detection time: 10ms
*
9
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (see catalog)

Summary of content (4 pages)