For gas Digital Pressure Sensor DP-101(A) / 102(A) SERIES Ver. 2 Conforming to EMC Directive Recognition Certification [DP-101(A)/102(A) only] Pressure Sensor Evolutions To Come 2013.11 panasonic.
Achieved further efficiency with 4 upgrades, keeping the same operability Note: The upgrade will be implemented from production in October 2013, based on stock status. Upgrade 1 Superior visibility Improved visibility in Digital Display Improvements to the digital display deliver a wide viewing angle along with increased clarity. The display pressure range and set pressure range have also been increased.
A new global standard Dual Display Direct setting “Current value” and “threshold value” can be checked at the same time! Current value Threshold value ect setting Dir Works like a dial control type sensor Main display Comparative Output 1 operation indicator Comparative Output 2 operation indicator Work as analog voltage output operation indicator in Multi-function type Mode selection key Dual display allows direct setting of threshold value Decrement key Increment key Previous model with single dis
Copy function helps operation to be accurate and quick Copy function reduces man-hours and human error Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when machinery design are changed, there would be less change in work orders. Setting details can be copied.
Setting is smooth and easy The sensor’s setting operation mode has a 3-level configuration to suit the frequency of use. The setting levels are clearly separated into “RUN mode” for operation settings that are carried out daily, “MENU SETTING mode” for basic settings, and “PRO mode” for special and detailed setting. These make setting operations easy to understand and easy to carry out.
Full range of performance and functions in a compact body All lineup models are compound pressure types High performance accomplished No sensor settings are required to switch between positive pressure and negative pressure, so that the number of registered part numbers can be decreased. Low pressure type The low pressure type displays measurements in 0.1 kPa at a resolution of 1/2,000 and has a response time of 2.5 ms (variable up to 5,000 ms), ±0.5 % F.S. temperature characteristics and ±0.1 % F.S.
Equipped with auto-reference / remote zero-adjustment functions, More precise pressure management is achieved with a minimum of effort If the reference pressure of the device changes, two functions are selectable. One is auto-reference function, which partially shift the comparative output judgment level by the amount that the reference pressure shifts. The other is remote zero-adjustment function, which can reset the display value to zero via external input.
Other useful functions Sub display can be customized Setting details can be recognized at a glance The sub display can be set to indicate any other desired values or letters apart from the threshold value. This eliminates the need for tasks such as affixing a label to the device to indicate the normal pressure value. The DP-100 setting details appear in the digital display.
Installation is also easy! Tight installation to panels is possible An exclusive mounting bracket that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available. Tight installation is possible Neat and space saving Front protection cover available MS-DP1-3 A single mounting hole! Ɣ An exclusive mounting bracket that supports tight installation is available Space savings can also be achieved even when an L-shaped mounting bracket is used.
DP-100 Flat installation on the wall by shifting the direction For short pressure port type of the pressure port Rc1/8 conversion bushing is available. Compatible For short pressure port type with previous model By mounting the flat attachment to DP-10Ƒ-M(-P), pressure port and cable can now be pulled out in downward, left or right directions. Flat mounting on surfaces such as the wall is made possible.
DP-100 OPTIONS Connector attached cable Designation Model No. Description &1 $ &Ƒ &1 $ 5 &Ƒ CN-14A-C1 CN-14A-C2 (Note) CN-14A-C3 CN-14A-C5 CN-14A-R-C1 CN-14A-R-C2 CN-14A-R-C3 CN-14A-R-C5 Length: 1 m 3.281 ft M8 connector attached cable CN-24A-C2 Length: 2 m 6.562 ft CN-24A-C5 For M8 plug-in connector type The connector on one end Length: 5 m 16.404 ft Cable outer diameter: ø4 mm ø0.
DP-100 SPECIFICATIONS Standard Item Model No. Type For low pressure DP-101(-M)(-P) DP-101-E-P DP-111-E-P-J DP-101-N(-P) Asia (Note 2) Europe M8 plug-in connector type North America (Note 2) Multi-function For low pressure For high pressure DP-101A(-M)(-P) DP-102A(-M)(-P) DP-101A-E-P DP-102A-E-P DP-111A-E-P-J DP-112A-E-P-J DP-101A-N(-P) DP-102A-N(-P) For high pressure DP-102(-M)(-P) DP-102-E-P DP-112-E-P-J DP-102-N(-P) Type of pressure Gauge pressure í100.0 to +100.0 kPa í101.0 to +101.0 kPa í1.
DP-100 I/O CIRCUIT AND WIRING DIAGRAMS DP-10Ƒ NPN output type Terminal No. I/O circuit diagram Standard type D2 2 Tr1 ZD1 D3 3 5V (Brown) +V (Black) Load Comparative output 1 Load 100 mA ma[. (White) Comparative output 2 + í 12 to 24 V DC ±10 % Sensor circuit D1 Sensor circuit Color code of connector attached cable Color code of connector attached cable 1 Tr2 Multi-function type Terminal No.
DP-100 I/O CIRCUIT AND WIRING DIAGRAMS '3 Ƒ ( 3 - PNP output type I/O circuit diagram Color code of connection cable Standard type (Brown) +V 1 ZD1 100 mA max. Tr1 4 ZD2 Tr2 + (Black) Comparative output 1 100 mA max. Load 2 (White) Comparative output 2 Load (Blue) 0 V í 12 to 24 V DC ±10 % ZD1 Tr1 100 mA max.
DP-100 PRECAUTIONS FOR PROPER USE Mounting Piping The MS-DP1-4 panel mounting bracket is available when switching from the DP2 / DP3 series. If connecting a commercially-available coupling to the pressure port, attach a 12 mm 0.472 in spanner (14 mm 0.551 in spanner for DP-100-E type) to the hexagonal section of the pressure port to secure it, and tighten at a torque of 9.8 N·m or less. If it is tightened using excessive torque, it may damage the coupling or the pressure port.
DP-100 PRECAUTIONS FOR PROPER USE Others PRO mode This product has been developed / produced for industrial use. Use within the rated pressure range. Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on. Avoid dust, dirt, and steam.
DP-100 DIMENSIONS (Unit: mm in) DP-10Ƒ The CAD data in the dimensions can be downloaded from the website. Sensor 42.5 1.673 30 1.181 25.5 1.004 20 0.787 7.5 9.5 0.295 0.374 12 0.472 20 0.787 30 1.181 R (PT) 1/ 8 male thread (North America: NPT 1/ 8) 1.5 0.059 Connector M5 female thread M3 female thread, 4 0.157 deep Europe Europe 10 7 0.394 0.276 14 0.551 G 1/ 8 male thread DP-10Ƒ-M(-P) Sensor 30 1.181 30 1.181 25.5 1.004 20 0.787 4.5 0.177 20 0.787 ø8.3 ø0.327 30 1.181 1.5 0.
DP-100 DIMENSIONS (Unit: mm in) MS-DP1-1 The CAD data in the dimensions can be downloaded from the website. Sensor mounting bracket (Optional) ø2.3 ø0.091 1 0.039 22 0.866 30 1.181 20 0.787 13 0.512 14.5 0.571 4.2 0.165 2-ø3.5 ø0.138 25.5 1.004 42.5 1.673 9.5 0.374 7.5 0.295 5.3 (0.209 ) 5.5 0.217 20 0.787 45 1.772 44 1.732 30 1.181 45 1.772 12 0.472 30 1.181 15 0.591 Sensor mounting bracket (Optional) 1.5 0.059 30 1.
DP-100 DIMENSIONS (Unit: mm in) MS-DP1-4 The CAD data in the dimensions can be downloaded from the website. Panel mounting bracket (Optional) Assembly dimensions Panel cut-out dimensions Mounting drawing with DP-10Ƒ ( 42.7 1.681 40 1.575 30 1.181 ) ( 9.7 0.382 36 1.417 26.5 1.043 6.5 0.256 3 0.118 ) Front protection cover (DPX-04) Panel thickness dimension 1 to 3.2 mm 0.039 to 0.126 in MS-DP1-7 36 +0.5 0 1.417+0.020 0 Connector R 1/ 8 male thread 80 3.150 12 0.472 42.7 1.681 40 30 1.
DIMENSIONS (Unit: mm in) The CAD data in the dimensions can be downloaded from the website. CN-14A(-R)-CƑ Connector attached cable (Optional, CN-14A-C2 is attached to the sensor) L 35 (1.378 ) Model No. 50 (1.969 ) (0.3158 ) (0.3158 ) ø3.7 ø0.146 cable Cable length L (mm in) CN-14A(-R)-C1 1,000 39.370 CN-14A(-R)-C2 2,000 78.740 CN-14A(-R)-C3 3,000 118.110 CN-14A(-R)-C5 5,000 196.850 Please contact ..........