User manual

4
Multifunction type
Common
Zero-adjustment function
The zero-adjustment function forcibly sets the pressure value to zero when
the pressure port is opened.
To force the pressure value to zero, simultaneously press + .
Key lock function
The key lock function protects settings from being changed inadvertently.
To lock, simultaneously press + .
To unlock, simultaneously press + .
Peak / bottom hold function
The peak / bottom hold functions display the peak value and bottom value
of the fluctuating pressure. The peak value is displayed on the main display
and the bottom value is displayed on the sub-display.
To set the peak / bottom hold function, simultaneously press + .
To release the peak / bottom hold function, simultaneously press +
.
Setting condition 1
Comparative output 1 set to: EASY (EASY mode)
Analog voltage output /
external input:
(Analog voltage output)
Setting condition 2
Comparative output 1 set to: EASY (EASY mode)
Analog voltage output /
external input:
AREF (Auto-reference input)
1
, or
ZERO (Remote zero-adjustment input)
2
1
For details, see page 7, section 13, AUTO-REFERENCE FUNCTION.
2
For details, see page 8, section 14, REMOTE ZERO-ADJUSTMENT
FUNCTION, MULTIFUNCTION TYPE.
Setting condition 3
Comparative output 1 set to: HYS (Hysteresis mode), or
WCMP (Window comparator mode)
Analog voltage output /
external input:
(Analog voltage output)
Setting condition 4
Comparative output 1 set to: HYS (Hysteresis mode), or
WCMP (Window comparator mode)
Analog voltage output /
external input:
AREF (Auto-reference input)
1
, or
ZERO (Remote zero-adjustment input)
2
1
For details, see page 7, section 13, AUTO-REFERENCE FUNCTION.
2
For details, see page 8, section 14, REMOTE ZERO-ADJUSTMENT
FUNCTION, MULTIFUNCTION TYPE.
MODE
Automatic
Blinks alternately
MODE
Automatic
Automatic
MODE
MODE
MODE
Automatic
Automatic
Blinks alternately
+
Automatic
Press
MODE
MODE
+
Automatic
Press
MODE
MODE
+
Automatic
Press
MODE
MODE
+
Press
Blinks alternately
MODE
MODE
+
Blinks alternately
Press