User manual

3 SERVICE DATA(SD)
Index Sub index Name R/W
Back up target
Format
Data length Default data
Description of settings
2 0 System-Command W UInteger 1byte
0x82 : Reset setting
0xA0 : Zero-adjustment setting
0xA1 : Remote zero-adjustment setting
0xA2 : Zero-adjust setting unset
0xA3 : Auto-reference setting
12 0 Device Access Locks R/W Record 2byte 0
Local User InterFace Lock
0 : UnLock , 8 : Lock
Main unit : Linked with key lock
16 0 Vendor Name R String 64byte
17 0 Vendor Text R String 64byte
18 0 Product Name R String 64byte
19 0 Product ID R String 64byte
20 0 Product Text R String 64byte
21 0 Serial Number R String 16byte
22 0 Hardware Version R String 8byte
23 0 Firmware Version R String 8byte
24 0 Application Specic Tag R/W String 32byte
37 0 Detailed Device Status R UInteger 12byte
40 0 Process-Data Input R UInteger 4byte
60
1 Threshold Value Setting 1 R/W Integer 2byte
DP-101
□:
-500 (-50.0)
DP-102
□:
0500 (0.500)
Threshold value of EASY mode
Low-side threshold value of window comparator
mode / hysteresis mode
DP101
□ : -1010 to 1010 0xFC0E to 0x03F2
DP102
□ : -101 to 1010 0xFF9B to 0x03F2
2 Threshold Value Setting 2 R/W Integer 2byte
DP-101
□:
-495 (-49.5)
DP-102
□:
0505 (0.505)
High-side threshold value of window comparator
mode / hysteresis mode
DP101
□ : -1010 to 1010 0xFC0E to 0x03F2
DP102
□ : -101 to 1010 0xFF9B to 0x03F2
61
1
Output Operation Setting of C/Q
Output
R/W UInteger 1byte
DP-101□
:1
DP-102□
:0
0 : N.O. 1 : N.C.
2
Sensing Output Setting of C/Q
Output
R/W UInteger 1byte 0x01
0x01 :
EASY mode
0x02 : Hysteresis mode
0x03 : Window comparator mode
3 Hysteresis Setting of C/Q Output R/W Integer 2byte 3 Hysteresis value 8-step setting : 1 to 8
63
1
Output Operation Setting of DO
Output
R UInteger 1byte Linkage with Index61_1
2
Sensing Output Setting of DO
Output
R UInteger 1byte Linkage with Index61_2
3 Hysteresis Setting of DO Output R Integer 2byte Linkage with Index61_3
66 0 Response Time Setting of Output R/W UInteger 1byte 1
1 : 2.5ms
2 : 5ms
3 : 10ms
4 : 25ms
5 : 50ms
6 : 100ms
7 : 250ms
8 : 500ms
9 : 1,000ms
A : 5,000ms
80 0 ECO Setting R/W UInteger 1byte 0
0 : Normal operation (ECO mode is OFF)
1 : Dimming mode (Std : The display becomes
dark)
3 : O mode (
FULL : The display is turned OFF
)
Index Sub index Name R/W
Back up target
Format
Data length Default data
Description of settings
82
1
Display Color Setting of Main-
display Selection
R/W UInteger 1byte 0
0 : Red when ON,Green when OFF
1 : Green when ON,Red when OFF
2 : Always red
3 : Always green
2
Display Setting of Sub-display
Selection
R/W UInteger 2byte 0
0 : Std (Displays threshold)
1 : OFF (Displays nothing)
2 : Unit (Presently selected pressure unit is
displayed)
3 : No** (Desired No. can be shown)
4 : Cust (
Desired numbers, alphabets and signs
can be shown
)
3 Display Speed Set R/W UInteger 1byte 0
0 : 250ms
1 : 500ms
2 : 1000ms
4 Peak / Bottom Hold Set R/W UInteger 1byte 0
0 : OFF
1 : ON
83 0 Pressure Unit Set R/W UInteger 1byte
DP-101
□ : 2
DP-102
□ : 1
1 : MPa (This cannot be selected in the case of
DP-101
□)
2 : kPa
84
1 No** Display Set R/W String 2byte 01 Two half-width numeric characters : 01 to 99
2 Custom Display Set R/W String 4byte AAAA
Four half-width alphanumeric characters
* Error is generated if any of the following characters
is entered.
T , j , k , m , p , s , x
85 0 Zero-adjust R UInteger 1byte
0 : Not executed
1 : In execution
163 0 Operating Time R UInteger 4byte Operating time per 1-hour unit [h]
164 0 Number of Data Save Operations R UInteger 4byte
Increments each time setting data is stored in
the nonvolatile memory.
168 0 Notication Flag Setting R/W UInteger 1byte
0 : Notify
1 : Do not notify
169 0 Notication Event Code R UInteger 2byte Newest event code readout
4 EVENT FUNCTION
Error indication
Event code
Error level
State
0x7710
Fault
Short circuit overcurrent
0x8CB0
Normal
Pressure applied during zero-adjustment
Information notication
0x8CB1
Normal External input outside the rated pressure range
0x1811
Fault
Pressure element abnormality
Display of measured value 0x8D00
Caution
Operating time exceeded
Display of measured value 0x8D01
Caution
Max. number of the nonvolatile memory save opera-tions exceeded
INSTRUCTION MANUAL
DP-100L Series
INDEX LIST
IMJE-DPLINDEX No.0061-91V
IO-Link setting file (IODD) can be downloaded from
our website ( http://panasonic.net/id/pidsx/global ).
1 PHYSICAL LAYER
Model No.
DP-101ZL3-M-P-
DP-102ZL3-M-P-
Baud rate COM3(230.4kbps)
Minimum cycle time 1ms
Process data length 4byte
Vendor ID 834
Device ID 0x060000 0x060001
2 PROCESS DATA(PD)
bit
7 6 5 4 3 2 1 0
PD0 Upper byte of pressure data
PD1 Lower byte of pressure data
PD2
Scale
 
DP-101ZL3-M-P-
□ : -1 (0.1kPa)
 
DP-102ZL3-M-P-
:
-3 (0.001MPa
0 (1kPa)
PD3
Assignment Remarks
bit
7 6 5 4 3 2 1 0
Control output
(DO)
0 : OFF
1 : ON
Fixed
0
Fixed
0
Fixed
0
Fixed
0
Information
notication
0 : No notication
1 : Notied
Error level
0 : Normal
1 : Caution
2 : Fault