User manual
INSTRUCTION MANUAL
High-performance Digital Display Pressure Sensor for IO-Link
DP-100L Series
ME-DP100L No.0061-90V
Thank you very much for purchasing Panasonic products. Read this Instruction Man-
ual carefully and thoroughly for the correct and optimum use of this product. Kindly
keep this manual in a convenient place for quick reference.
WARNING
● Never use this product as a sensing device for personnel protection.
● In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-
tion applicable in each region or country.
● This product is designed for use with non-corrosive gas. It cannot be used for liq-
uid or corrosive gas.
● A product intended for use in Japan conforms to the Japanese Measurement Act.
Do not use a product intended for use overseas in Japan.
1 PART DESCRIPTION
Output operation
indicator 1
(Notes: 1)
Output operation
indicator 2
Lights up when com-
parative output is ON
Mode selection key
Unit display
Main display
Sub display
Setting value
DOWN key
Setting value UP key
Connection
connector
Pressure port
M5 female screw
Notes: 1)
During IO-Link
non communication
During IO-Link com-
munication
Function
Lights up when com-
parative output is ON
(Notes 2)
Flashes
Notes: 2) Synchronized with output operation indicator 2
2 PIPING
● To connect a commercial coupler to the pressure port, manually hold the main
unit of the product and install the coupler by tightening it to a tightening torque
of 1N∙m or less. The commercial coupler or pressure port section will be dam-
aged if the tightening torque is excessive.
Wrap sealing tape around the coupler when connecting to prevent leaks.
3 MOUNTING
● The sensor mounting bracket
MS-DP1-1
is available as an option. When mounting the sen-
sor onto the sensor mounting bracket, etc., the tightening torque should be 0.5N·m or less.
M3 (length 6mm) screws
with washers
(Accessory with
MS-DP1-1
)
Sensor mounting bracket
MS-DP1-1
(Optional)
● The panel mounting bracket
MS-DP1-2
(optional) and
MS-DP1-4
(optional), as well
as the front cover
MS-DP1-3
(optional) and
DPX-04
(optional) are also available.
● The type of the front cover is dierent depending on the applied mounting bracket.
Use
MS-DP1-3
for
MS-DP1-2
, and
DPX-04
for
MS-DP1-4
.
● For mounting of the panel mounting bracket, refer to the Instruction Manual en-
closed with
MS-DP1-2
or
MS-DP1-4
.
4 WIRING
Connection method
● Insert the cable with connector (included in
this product) into the connection connector
section of this product as shown in the gure
to the right.
Disconnection method
● Pressing the release lever of the cable with
connector, pull out the connector.
Cable with connector
provided (on the main-unit
connection connector
side)
Release lever
<Recommended product>
Contact: SPHD-001T-P0.5
Housing: PAP-04V-S
[JST Mfg. Co., Ltd.]
Note: Do not pull by holding the cable without pressing the release lever, as this can cause cable break or connector
break.
<Connection connector pin arrangement>
1 2 3 4
Connector pin No.
Wiring color/
M12 connector
Terminal
No.
Terminal name
1 Brown / 1 +V
2 Black / 4 IO-Link communication (C/Q)
3 White / 2 Control output (DO)
4 Blue / 3 0V
5 CONNECTION
●
When connected to IO-Link master
This product IO-Link master
(Brown / 1) +V +V
(Black / 4) C/Q C/Q
(White / 2) DO DI
(Blue / 3) 0V 0V
●
When used as general-purpose sensor
(Brown / 1) +V
(Black / 4) C/Q Note
(White / 2) DO
(Blue / 3) 0V
Load
Load
+
-
24V DC
±10%
<Terminal arrangement of M12 connector type>
• Recommended
extension cable
Extension cable with connectors
on both ends
XS5W series
[OMRON Corporation]
1
4
2
3
Terminal No. Terminal name
1 +V
2 Control output (DO)
3 0V
4 IO-Link communication (C/Q) Note
Note: When the product is used as a general-purpose sensor, the IO-Link communication (C/Q) is generated in the
same way as control output (DO)
How to mount M12 connector
If the xed ring loosens, the connector will come o, causing this product to generate
a communication error.
Before use, be sure to check that the xed ring is not loose.
●
Firmly tighten the xed ring by rotating it.
Fixed ring
6 LIST OF FUNCTIONS
Function Setting on main unit
IO-Link communication setting
(Note)
Comparative output mode
setting
Select from EASY mode / Hysteresis mode /
Window comparator mode
Index61_2
Threshold value setting
EASY mode : Threshold value
Hysteresis mode /
Window comparator mode : Lo side
Index60_1
Hysteresis mode /
Window comparator mode : Hi side
Index60_2
Zero-adjust setting Execute / Cancel Index2
Key lock Set / release Index12
Peak / bottom hold
function
Setting Index82_4
Comparative output mode
setting
N.O. / N.C. Index61_1
Response time setting
Select from 10 steps Index66
Displayed color of the main
display selection
Select from 4 modes Index82_1
Pressure unit selection
Select from 2 modes
DP-101□ is xed
Index83
Display setting of Sub-
display selection
Select from 5 modes Index82_2
No. display setting
Index84_1
Custom display setting Index84_2
Display speed selection Select from 3 steps Index82_3
Hysteresis xed value
selection
Select from 8 steps Index61_3
Eco mode setting Select from 3 modes Index80
Setting check code
8 digit indication
-
Reset setting Execute Index2
Remote zero-adjust
setting
- Index2
Zero-adjust execution
notication
- Index85
Auto-reference setting - Index2
Operating time - Index163
Number of data save
operations
- Index164
Notication Flag Setting - Index168
Notication Event Code - Index169
Note: For the IO-Link communication setting, refer to the attached sheet, “Index List.”(IMJE-DPLINDEX)
7 OUTPUT MODE AND OUTPUT OPERATION
● The EASY mode, hysteresis mode or window comparator mode can be selected as
the output mode for comparative output.
Refer to “
9
MENU SETTING MODE
” for details.
EASY mode
● ON / OFF of the comparative output is controlled in this mode.
Pressure
P
0
ON
OFF
Comparative
output
H (Hysteresis)
H: Hysteresis xed (Note)
Notes: Hysteresis can be xed in 8 steps.
Refer to
<Hysteresis xed value selection>
in “
10
PRO MODE
” for setting.
Hysteresis mode
● This mode controls ON / OFF by arbitrarily setting the hysteresis of the compara-
tive output.
0
Pressure
Comparative
output
H (Hysteresis)
Hi
Lo
ON
OFF
H: 1digit or more
Note: “ ” or “ ” is displayed on the sub-display.