Datasheet

DP-100
10
SPECIFICATIONS
NO / NC (selectable by key operation)
EASY mode / Hysteresis mode / Window comparator mode
Minimum 1 digit (variable) (however, 2 digits when using psi unit)
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Incorporated
Gauge pressure
Non-corrosive gas
For low pressure: kPa, kgf/cm
2
, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm
2
, bar, psi
12 to 24 V DC
10 % Ripple P-P 10 % or less
Normal operation: 840 mW or less (Current consumption 35 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less at STD (Current consumption 25 mA or less at 24 V supply voltage)
480 mW or less at FULL (Current consumption 20 mA or less at 24 V supply voltage)
<Asian, North American (NPN output)>
NPN open-collector transistor
Maximum sink current: 100 mA
Applied voltage: 30 V DC or less (between comparative output and 0 V)
Residual voltage: 2 V or less (at 100 mA sink current)
<European, North American (PNP output)>
PNP open-collector transistor
Maximum source current: 100 mA
Applied voltage: 30 V DC or less (between comparative output and V)
Residual voltage: 2 V or less (at 100 mA source current)
<
Asian, North American (NPN output)
>
ON voltage: 0.4 V DC or less
OFF voltage: 5 to 30 V DC, or open
Input impedance: 10 k approx.
Input time: 1 ms or more
<
European, North American (PNP output)
>
ON voltage: 5 V to V DC
OFF voltage: 0.6 V DC or less, or open
Input impedance: 10 k approx.
Input time: 1 ms or more
4 digits
4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
(
Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON
)
Orange LED Orange LED
(
Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting
)
IP40 (IEC)
10 to 50 C 14 to 122 F, Storage: 10 to 60 C 14 to 140 F
35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 M, or more, with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in amplitude, in X, Y and Z directions for two hours each (when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude, in X, Y and Z directions for two hours each)
100 m/s
2
acceleration (10 G approx.) in X, Y and Z directions for three times each
Asian: M5 female thread R (PT)
1
/8 male thread, European: M5 female thread G
1
/8 male thread, North American: M5 female thread NPT
1
/8 male thread
Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Brass (nickel plated), Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connector
Extension up to total 100 m 328.084 ft (less than 10 m 32.808 ft when conforming to CE marking) is possible with 0.3 mm
2
, or more, cable
Net weight: 40 g approx., Gross weight: 135 g approx.
CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc.
Within 1 % F.S. (at 20 C 68 F)
Within 0.5 % F.S. (at 20 C 68 F)
Within 1 % F.S. (at 20 C 68 F)
Within 0.5 % F.S. (at 20 C 68 F)
DP-102-E-P
DP-102-N(-P)
DP-101-E-P
DP-101-N(-P)
DP-102A-E-P
DP-102A-N(-P)
DP-101A-E-P
DP-101A-N(-P)
DP-102DP-101 DP-102ADP-101A
Environmental resistance
Power consumption
Type of pressure
Rated pressure range
Set pressure range
Pressure withstandability
Applicable fluid
Selectable unit
Supply voltage
Comparative output
Output voltage: 1 to 5 V DC
Zero point: within 3 V 5 % F.S.
Span: within 4 V 5 % F.S.
Linearity: within
1 % F.S.
Output impedance: 1 k approx.
Output voltage: 0.6 to 5 V
Zero point: within 1 V5 % F.S.
Span: within 4.4 V5 % F.S.
Linearity: within
1 % F.S.
Output impedance: 1 k approx.
Output operation
Output modes
Hysteresis
Repeatability
Response time
Short-circuit protection
Temperature characteristics
Pressure port
Material
Connecting method
Cable extension
Weight
Accessories
Pollution degree
Ambient temperature
Ambient humidity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
Standard
For low pressure For high pressure For low pressure For high pressure
100.0 to 100.0 kPa 0.100 to 1.000 MPa 100.0 to 100.0 kPa 0.100 to 1.000 MPa
1.020 to 1.020 kgf/cm
2
1.000 to 1.000 bar
14.50 to 14.50 psi
750 to 750 mmHg
29.5 to 29.5 inHg
100 to 1,000 kPa
1.02 to 10.20 kgf/cm
2
1.00 to 10.00 bar
14.6 to 145.0 psi
1.020 to 1.020 kgf/cm
2
1.000 to 1.000 bar
14.50 to 14.50 psi
750 to 750 mmHg
29.5 to 29.5 inHg
100 to 1,000 kPa
1.02 to 10.20 kgf/cm
2
1.00 to 10.00 bar
14.6 to 145.0 psi
500 kPa 1.5 MPa 500 kPa 1.5 MPa
1.020 to 1.020 kgf/cm
2
1.000 to 1.000 bar
14.50 to 14.50 psi
750 to 750 mmHg
29.5 to 29.5 inHg
100 to 1,000 kPa
1.02 to 10.20 kgf/cm
2
1.00 to 10.00 bar
14.6 to 145.0 psi
1.020 to 1.020 kgf/cm
2
1.000 to 1.000 bar
14.50 to 14.50 psi
750 to 750 mmHg
29.5 to 29.5 inHg
100 to 1,000 kPa
1.02 to 10.20 kgf/cm
2
1.00 to 10.00 bar
14.6 to 145.0 psi
0.1 % F.S. (within 2 digits) 0.2 % F.S. (within 2 digits) 0.1 % F.S. (within 2 digits) 0.2 % F.S. (within 2 digits)
Multi-function
Type
Item
European
North American (Note 2)
Asian
Model No.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were ambient temperature 20 C 68 F.
2) Model Nos. of North American standard type having the suffix -P
are PNP output type.
Analog voltage output
Indicator
Displayable pressure range
Display
External input
Auto-reference function /
Remote zero-adjustment
function
100.0 to 100.0 kPa
0.100 to 1.000 MPa
100.0 to 100.0 kPa
0.100 to 1.000 MPa
100.0 to 100.0 kPa
0.100 to 1.000 MPa
100.0 to 100.0 kPa
0.100 to 1.000 MPa
10/2006