MENU SETTING MODE
9
٨
٨
٨
When the mode selection key is held down for two seconds in the
RUN mode, the menu setting mode will open.
The mode will change to the RUN mode when the mode selection key
is held down during this setting process.
The leftmost setting items are the default settings (factory settings).
Setting item Description
Comparative output 1
output mode setting
Sets the output operation of comparative output 1.
Comparative output 2
output mode setting
(Standard type only)
Sets the output operation of comparative output 2.
Pressure unit can be changed.
Response time setting
Sets the response time.
The response time can be selected from 2.5ms, 5ms, 10ms, 25ms, 50ms,
100ms, 250ms, 500ms, 1,000ms or 5,000ms.
Displayed color of the
main display selection
Displayed color of the main indicator can be changed.
Unit selection
N.O. / N.C. selection
Normal open (N.O.) or normal close (N.C.) can be selected.
Analog voltage output /
external input selection
(High-function type
only)
Selects analog voltage output, auto-reference input, or remote zero-ad-
justment input.
Notes: 1)
2)
3)
4)
If the comparative output 2 output mode setting is set to ' ', the display of
N.O. / N.C. selection is the same as the high-function type.
The default setting of the high pressure type is ' ', and that of the low pressure type is ' '.
The default setting of the low pressure type is ' '. ' ' is not displayed.
This is not displayed on the high-pressure type.
Standard type
High-function type
(OFF mode)
<RUN mode>
<Comparative output 1 output mode setting>
<Analog voltage output / external input selection>
<Comparative output 2 output mode setting> (Note 1)
(EASY mode)
(2.5ms) (5ms)
(5,000ms)
MODE
MODE
MODE
(N.O.) (N.C.)
<N.O. / N.C. selection> (Note 2)
MODE
MODE
࡮࡮࡮࡮࡮
MODE
<RUN mode>
MPa(Note 3)
(kPa) (bar)
(mmHg)
(inchHg)(Note 4) (psi)
(kgf/cm
2
)
<Response time setting>
<Display color of the main display selection>
Hysteresis
mode
Window
comparator
mode
Analog
voltage
output
Remote
zero-adjust-
ment input
(EASY mode)
Hysteresis
mode
<N.O. / N.C. selection> (Note 1) (Note 2)
Output 1: N.O.
Output 2: N.O.
Output 1: N.C.
Output 2: N.O.
Output 1: N.O.
Output 2: N.C.
Output 1: N.C.
Output 2: N.C.
Window
comparator
mode
Standard type
High-function type
Press for 2 sec.
MODE
Red when ON
Green when OFF
Red when ON
Green when OFF
(Always red)
(Always green)
Auto-refer-
ence input
High-function type
Common
<Setting condition 7>
Comparative output 1 output mode: ' ' (EASY mode)
Analog voltage output / external input selection: ' ' (Analog voltage output)
<RUN mode state>
<Setting condition 9>
Comparative output 1 output mode: ' ' (Hysteresis mode) or
' ' (Window comparator mode)
Analog voltage output / external input selection: ' ' (Analog voltage output)
٨ The zero-adjustment function forcibly sets the pressure to 'zero' when
the pressure port is opened.
Zero-adjustment function
٨ The key lock function prevents key operations so that the conditions set
in each setting mode are not inadvertently changed.
Key lock function
<Key lock set>
<Key lock released>
Hold
down
Hold
down
Hold
down
(Key lock set)
MODE
(Key lock released)
٨
٨
The peak / bottom hold functions display the peak value and bottom val-
ue of the fluctuating pressure.
The peak value is displayed on the main display and the bottom value is
displayed on the sub-display
.
Peak / bottom hold function
MODE
Hold
down
<Setting condition 8>
Comparative output 1 output mode: ' ' (EASY mode)
Analog voltage output / external input selection: ' ' (Auto-reference input) or
' '
(Remote zero-adjustment input)
<Setting condition 10>
Comparative output 1 output mode: ' ' (Hysteresis mode) or
' ' (Window comparator mode)
Analog voltage output / external input selection: ' ' (Auto-reference input) or
' '
(Remote zero-adjustment input)
Note: Auto-reference value and remote zero-adjustment value are displayed.
For details, refer to ' AUTO-REFERENCE FUNCTION ' and ' REMOTE
ZERO-ADJUSTMENT FUNCTION '.
12 13
Automatic
Automatic
Automatic
<RUN mode state>
Automatic
Automatic
MODE
<RUN mode state>
(Note)
Automatic
MODE
Blinks alternately
<RUN mode state>
(Note)
Automatic
Automatic
MODE
MODE
MODE
MODE
Blinks alternately
Blinks alternately