Specifications

Ceiling-Suspended Air Conditioners and Heat Pumps
Ceiling Suspended Air Conditioners
& Heat Pumps
Ceiling Suspended Air Conditioners
& Heat Pumps
29 30
F1
F2
F3
F4
F5
60˚
Heating F1 F5
Cooling F1 F3
Ceiling - Suspended
Air Conditioners Heat Pumps
Model No.
26PST1U6 36PST1U6 42PST1U6 26PET1U6 36PET1U6 42PET1U6
Unit Model No. Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
S-26PT1U6 U-26PS1U6 S-36PT1U6 U-36PS1U6 S-42PT1U6 U-42PS1U6 S-26PT1U6 U-26PE1U6 S-36PT1U6 U-36PE1U6 S-42PT1U6 U-42PE1U6
Performance & Electrical Ratings
Capacity Cooling Btu/h 24,400 (9,500~24,400) 31,200 (9,500~31,200) 39,000 (9,500~39,000) 24,400 (9,500~24,400) 31,200 (9,500~31,200) 39,000 (9,500~39,000)
Heating Btu/h --- --- --- 30,800 (8,000~30,800) 37,400 (8,000~37,400) 44,500 (8,000~44,500)
Moisture Removal High Pints/H 7.7 10.0 12.6 7.7 10.0 12.6
Dry Air Flow Hi / Med / Low CFM 550 / 490 / 460 1,100 / 930 / 750 1,130 / 950 / 775 550 / 490 / 460 1,100 / 930 / 750 1,130 / 950 / 775
SEER Cooling 14.5 15.1 15.6 14.5 15.1 15.6
EER Cooling 8.5 8.10 9.4 8.5 8.10 9.4
HSPF Heating --- --- --- 9.4 8.8 9.5
Power Supply V, Phase, Hz 230 / 208 / 1 / 60 230 / 208 / 1 / 60 230 / 208 / 1 / 60 230 / 208 / 1 / 60 230 / 208 / 1 / 60 230 / 208 / 1 / 60
Running Amps Cooling A 15.6 / 17.3 18.2 / 20.1 21.1 / 23.3 15.6 / 17.3 18.2 / 20.1 21.1 / 23.3
Heating A --- --- --- 16.4 / 18.1 15.6 / 17.3 18.6 / 20.6
Power Input Cooling W 2,880 / 2,880 3,840 / 3,840 4,140 / 4,140 2,880 / 2,880 3,840 / 3,840 4,140 / 4,140
Heating W --- --- --- 3,000 / 3,000 3,250 / 3,250 3,630 / 3,630
Fuse or Circuit Breaker Capacity A 15 30 15 35 15 40 15 30 15 35 15 40
Features
Controls Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor Microprocessor
Low Ambient Control (for Cooling) Built-in 0˚F Built-in 0˚F Built-in 0˚F Built-in 0˚F Built-in 0˚F Built-in 0˚F
Wireless Remote Controller(optional) CZ-RWSU2U, CZ-RWSC1U CZ-RWSU2U, CZ-RWSC1U CZ-RWSU2U, CZ-RWSC1U CZ-RWSU2U, CZ-RWSC1U CZ-RWSU2U, CZ-RWSC1U CZ-RWSU2U, CZ-RWSC1U
Wired Remote Controller (included) CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2 CZ-RTC2
Fan Speeds
3 and Automatic Control / Variable 3 and Automatic Control / Variable 3 and Automatic Control / Variable 3 and Automatic Control / Variable 3 and Automatic Control / Variable 3 and Automatic Control / Variable
Timer 7 Days/6 Events 7 Days/6 Events 7 Days/6 Events 7 Days/6 Events 7 Days/6 Events 7 Days/6 Events
Air Deflection Horizontal --- --- --- --- --- ---
Vertical Automatic Automatic Automatic Automatic Automatic Automatic
Air Filter Washable Washable Washable Washable Washable Washable
Refrigerant R-410A R-410A R-410A R-410A R-410A R-410A
Refrigerant control Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve
Operation Sound
In(Hi / Me / Lo) dB-A
39 / 37 / 33 42 / 40 / 35 44 / 41 / 37 39 / 37 / 33 42 / 40 / 35 44 / 41 / 37
Outdoor(Hi) dB-A 49 52 53 49 52 53
Refrigerant Piping Type Flare Flare Flare Flare Flare Flare
Discharge inches 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
Suction inches 5/8” 5/8” 5/8” 5/8” 5/8” 5/8”
Refrigerant Pipe Length Ft. Max. 165 Max. 165 Max. 165 Max. 165 Max. 165 Max. 165
Elevation Difference* Outdoor Above Ft. Max. 100 Max. 100 Max. 100 Max. 100 Max. 100 Max. 100
Outdoor Below Ft. Max. 50 Max. 50 Max. 50 Max. 50 Max. 50 Max. 50
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height inches 7-17/32" 30-23/32" 9-7/16" 30-23/32" 9-7/16" 48-7/16" 7-17/32" 30-23/32" 9-7/16" 30-23/32" 9-7/16" 48-7/16"
Width inches 51-3/16" 37" 62-1/32" 37" 62-1/32" 37" 51-3/16" 37" 62-1/32" 37" 62-1/32" 37"
Depth inches 26-3/8" 13-3/8" 26-3/8" 3-3/8" 26-3/8" 13-3/8" 26-3/8" 13-3/8" 26-3/8" 13-3/8" 26-3/8" 13-3/8"
Net Weight Lbs. 57.0 128.0 84.0 143.0 84.0 220.0 57.0 128.0 84.0 143.0 84.0 220.0
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalog)
Outdoor Unit
U-26PS1U6 / U-26PE1U6
Outdoor Unit
U-36PS1U6 / U-36PE1U6
Outdoor Unit
U-42PS1U6 / U-42PE1U6
Indoor Unit
S-26PT1U6
Indoor Unit
S-36PT1U6 / S-42PT1U6
Wired Remote Controller
(Included)
Wirless Remote Controller
(optional)
Wired Remote Controller
(Included)
Wirless Remote Controller
(optional)
(optional)
(Heat Pump) (Heat Pump)
(optional)
(Heat Pump)
(optional)
(Field
Supplied)
(cooling)
26PST1U6 36PST1U6 / 42PST1U6
26PET1U6 36PET1U6 / 42PET1U6
Improved Serviceability / Easy
Installation
Improved accessibility to electronic
components (control box) for serving.
External suspension method.
Installation time can be shortened.
The ceiling-mounted unit is equipped with a highly efficient, multi-blade centrifugal fan that generates a powerful,
yet gentle airflow throughout the room.
A redesigned aerodynamically tested louver structure minimizes operational sound even at high fan speed.
Quiet Operation
Auto-Louver Function Provides Optimum Airflow During Heating
or Cooling Operation
Fresh Air Intake Capability and
Duct Extension
Ceiling-suspended models have the capability of bringing fresh
air from outside using an air-intake duct (field supplied).
Auto-louver function is a standard feature which provides optimum airflow during heating or cooling operation.
Angle of louver is automatically set for heating or cooling. For example, when heating with fan speed set
to low, the discharge is aimed downward so that warm air reaches the floor. The louver angle can be set to
between 4°F above and 80°F below the horizontal in five steps. An auto-sweep function to distribute the
airflow over a wide area is also provided. Wind direction is adjusted automatically in both heating and cooling
operation. The louver can also be set
to swing automatically from F1
to F5 in any operation mode (heat
pump type only).