Specifications

11 12
Wall-Mounted Heat Pumps
Wall Mounted Heat Pumps
Wall Mounted Heat Pumps
Wall-Mounted Heat Pumps
Performance & Electrical Ratings
Wall Mounted Heat Pumps
Model No. XE9PKUA XE12PKUA
Unit Model No.
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
CS-XE9PKUA CU-XE9PKUA CS-XE12PKUA CU-XE12PKUA
Capacity
Cooling Btu/h 11,500(2,800~14,000)
Heating Btu/h 12,000(3,000~18,000) (10,600 at 17˚F) 13,800(3,000~23,000) (13,500 at 17˚F)
Moisture Removal High Pints/H 1.3 2.3
Dry Air Flow High CFM 405 530
SEER Cooling 28.5 25.5
EER Cooling 16.1 14.35
HSPF Heating 12.5 12.0
Power Supply V, Phase, Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz
Running Amps
Cooling A 2.5/2.8 3.8/4.2
Heating A 4.0/4.5 5.2/5.8
Power Input
Cooling W 540(150-850) 800(150-1,050)
Heating W 860(150-1,650) 1,150(150-2,100)
Back-up Heater kW --- ---
Fuse or Circuit Breaker Capacity A 15 20
Features
Controls Microprocessor Microprocessor
Low Ambient Control Eqipped Equipped
Wireless Remote Controller Included Included
Wired Remote Controller (optional) CZ-RD516C-1 CZ-RD516C-1
Fan Speeds 5 Speeds + Auto 5 Speeds + Auto
Timer 24hr Program 24hr Program
Air Deflection
Horizontal Manual Manual
Vertical Automatic Automatic
Air Filter Washable + Anti Microbial Filter Washable + Anti Microbial Filter
Refrigerant R-410A R-410A
Refrigerant control Electric Expansion Valve Electric Expansion Valve
Operation Sound
In(Hi / Lo/ Q-Lo) dB-A 42 / 25 / 20 45 / 28 / 20
Outdoor(Hi) dB-A 48 49
Refrigerant Piping
Type Flare Flare
Discharge inches 1/4” 1/4”
Suction inches 3/8” 1/2”
Refrigerant Pipe Length Ft. Max. 66 Max. 66
Elevation Difference*
Outdoor Above Ft. Max. 49 Max. 49
Outdoor Below Ft. Max. 49 Max. 49
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height inches 11-5/8” 27-3/8” 11-5/8” 27-3/8”
Width inches 34-9/32” 34-15/32” 34-9/32” 34-15/32”
Depth inches 10-1/16” 12-5/8” 10-1/16” 12-5/8”
Net Weight Lbs. 24 97 24 97
8,700(2,800~12,000)
Micro-
processor
Control
Wireless
Control
Wired
Control
Self
Diagnose
Dry
5 Fan
speeds
Air Sweep Louver
Auto-
change
over
Night
setback
Hot Start 24hr timer
Weekly
Timer
System
Controller
Filter sign
Auto
Restart
Fresh
Air intake
Branch
Extension
Drain
Pump
Low
Ambient
Operation
Elect.Valve
ODP=0
Refrigerant
Quiet
Anti-
microbial
Filt.
Blue Fin
ECONAVI
Room Freeze
Protection
1hr
off timer
E18NKUA / E24NKUA
Wall Mounted Heat Pumps
Model No.
E9NKUA E12NKUA E18NKUA E24NKUA
Unit Model No.
Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
CS-E9NKUAW CU-E9NKUA CS-E12NKUAW CU-E12NKUA CS-E18NKUA CU-E18NKUA CS-E24NKUA CU-E24NKUA
Performance & Electrical Ratings
Capacity
Cooling Btu/h 8,500(4,100~10,200) 12,000(4,100~13,300) 17,100(5,800-19,800) 24,000(5,800-27,200)
Heating Btu/h 11,200(4,100~14,100) 13,800(4,100~16,300) 20,400(5,800-20,800) 28,800(5,800-29,200)
Moisture Removal High Pints/H 1.3 2.5 3.0 7.6
Dry Air Flow High CFM 395 425 650 650
SEER Cooling 21.0 20.0 18.0 17.5
EER Cooling 13.1 12.0 13.2 10.2
HSPF Heating 10.5 10.6 8.5 8.5
Power Supply V, Phase, Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz
Running Amps
Cooling A 3.1(~7) 4.7(~7.8) 6.30 / 7.20 10.80 / 11.90
Heating A 5.4(~7) 5.8(~7.8) 7.50 / 8.60 11.40 / 12.60
Power Input
Cooling W 650(250-850) 1,000(250-1,150) 1,300(430-1,600) 2,350(430-2,720)
Heating W 1,150(200-1,500) 1,300(200-1,710) 1,600(380-1,650) 2,500(380-2,660)
Back-up Heater kW --- --- --- ---
Fuse or Circuit Breaker
Capacity A 15 15 20 20
Features
Controls Microprocessor Microprocessor Microprocessor Microprocessor
Low Ambient Control Equipped Equipped Equipped Equipped
Wireless Controller Included Included Included Included
Wired Remote Controller(optional)
CZ-RD516C-1 CZ-RD516C-1 CZ-RD516C-1 CZ-RD516C-1
Fan Speeds 5 Speeds + Auto 5 Speeds + Auto 5 Speeds + Auto 5 Speeds + Auto
Timer 24hr Program 24hr Program 24hr Program 24hr Program
Air Deflection
Horizontal Manual Manual Automatic Automatic
Vertical Automatic Automatic Automatic Automatic
Air Filter Washable + Anti Microbial Filter Washable + Anti Microbial Filter Washable + Anti Microbial Filter Washable + Anti Microbial Filter
Refrigerant R-410A R-410A R-410A R-410A
Refrigerant control Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve Electric Expansion Valve
Operation Sound
In(Hi / Me / Lo/ Qt) dB-A 40 / 25 / 20 43 / 28 / 20 47/39/36 48/40/37
Outdoor(Hi) dB-A 47 48 49 51
Refrigerant Piping
Type Flare Flare Flare Flare
Discharge inches 1/4” 1/4” 1/4” 1/4”
Suction inches 3/8” 1/2” 1/2” 5/8”
Refrigerant Pipe Length
Ft. Max. 66 Max. 66 Max. 100 Max. 100
Elevation Difference*
Outdoor Above Ft. Max. 49 Max. 49 Max. 49 Max. 49
Outdoor Below Ft. Max. 49 Max. 49 Max. 49 Max. 49
Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit
Height inches 11-7/16” 21-9/32” 11-7/16” 21-9/32” 11-7/16” 31-5/16” 11-7/16” 31-5/16”
Width inches 34-9/32” 30-23/32” 34-9/32” 30-23/32” 42-5/32” 34-15/32” 42-5/32” 34-15/32”
Depth inches 8-1/16” 11-13/32” 8-1/16” 11-13/32” 9-9/32” 12-5/8” 9-9/32” 12-5/8”
Net Weight Lbs. 20.0 82.0 20.0 82.0 26.0 132.0 26.0 132.0
Indoor Unit
CS-E9NKUAW / CS-E12NKUAW
Outdoor Unit
CU-E9NKUA / CU-E12NKUA
Outdoor Unit
CU-E18NKUA / CU-E24NKUA
Indoor Unit
CS-E18NKUA / CS-E24NKUA
E9NKUA / E12NKUAXE9PKUA / XE12PKUA
(optional)(optional)
Wired
Remote Controller
(CZ-RD516C-1)
(Optional)
Wired
Remote Controller
(CZ-RD516C-1)
(Optional)
(E18 Only)
Wireless
Remote
Controller
Wireless
Remote
Controller
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the P.34 in the catalog for more detail.)* This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the P.34 in the catalog for more detail.)
Indoor Unit
CS-XE9PKUA / CS-XE12PKUA
Outdoor Unit
CU-XE9PKUA / CU-XE12PKUA
Wireless
Remote
Controller
Wired
Remote Controller
(CZ-RD516C-1)
(Optional)
EXTERIOS