Datasheet
Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use.
Should a safety concern arise regarding this product, please be sure to contact us immediately.
Plastic Film Capacitors
1 2 3 4 5 6 7 8 9 11 12
E C Q E
Product code Dielectric &
construction
SuffixRated voltage Capacitance SuffixCap. Tol.
10
B
Code
Blank
B
Z
2
3
6
Lead Form
Straight
Crimped lead
Cut lead
Straight taping (Ammo)
Crimped taping (Ammo)
Crimped taping (Ammo)
2 250 V.DC
1A 125 V.AC
J ±5 %
K ±10 %
1 2 3 4 5 6 7 8 9 11 12
E C Q E B
Product code Dielectric &
construction
Cap. Tol.Rated voltage Capacitance SuffixSuffix
10
R
●
Self-healing property
●
Small size
●
Excellent electrical characteristics
●
Flame retardant epoxy resin coating
●
RoHS directive compliant
●
General purpose usage
✽ Please contact us when applications are CDI, ignitor etc.
●
Odd size taping
Non-inductive construction using metallized polyester
fi lm with fl ame retardant epoxy resin coating
Metallized Polyester Film Capacitor
Type : ECQE(B)
Category temp. range
(Including temperature-rise on unit surface)
250 V.DC
– 40 °C to +105 °C
125 V.AC – 40 °C to +105 °C
Rated voltage
250 V.DC,
125 V.AC
(250 V.DC : Derating of rated voltage by 1.25 %/°C at more than 85 °C)
Capacitance range 0.010 F to 4.7 F
Capacitance tolerance ±5 %(J), ±10 %(K)
Dissipation factor (tan d) tan d < 1.0 % ( 20 °C, 1 kHz )
Withstand voltage
• Rated volt. : 250 V.DC
Between terminals : Rated volt. (V.DC)×150 %, 60 s
• Rated volt. : 125 V.AC
Between terminals : Rated volt. (V.AC)×230 %, 60 s
Between terminals to enclosure : 1500 V.AC, 60 s
Insulation resistance (IR)
250 V.DC
C < 0.33 F : IR > 9000 MΩ (20 °C, 100 V.DC, 60 s)
C > 0.33 F : IR > 3000 MΩ µF (20 °C, 100 V.DC, 60 s)
125 V.AC
C < 0.47 F : IR > 2000 MΩ (20 °C, 500 V.DC, 60 s)
C > 0.47 F : IR > 3000 MΩ µF (20 °C, 100 V.DC, 60 s)
✽
In case of applying voltage in alternating current (50 Hz or 60 Hz sine wave) to a capacitor with DC rated voltage,
please refer to the page of “Permissible voltage (R.M.S) in alternating current corresponding to DC rated voltage”.
✽
Voltage to be applied to ECQE1A (B) is only sine wave (50 Hz or 60 Hz).
Features
Recommended applications
Explanation of part number
Speci cations
Feb. 201601