Submittal Sheet

Specification Submittal Data / Panasonic Ventilation Fan
Description
Energy Recovery Ventilator provides a tempered
air supply, humidity control, and a balanced
amount of exhaust to help maintain neutral
pressure throughout the home. Panasonic ERV
shall not be installed in a bathroom. Only one
unit is needed for a 1,750 sq. ft. 2 bedroom
home to meet the ASHRAE 62.2 ventilation
requirement.
Motor/Blower:
• Totally enclosed AC condenser motor rated for
continuous run.
• Power rating shall be 120 volts and 60 Hz.
• Two highly efcient blower wheels running on
single motor for lower power consumption and
decreased noise.
• Motor equipped with thermal cut-off fuse
control.
Housing:
• Rust proof paint, galvanized steel body.
• Dual 4” intake and exhaust ducts.
• Built in backdraft damper on exhaust duct.
• Filters on supply and exhaust air extend the
life of the ERV core.
• Expandable mounting bracket up to 16” on
center.
Grille:
• Attractive design using ABS material.
• Attaches directly to housing with torsion
springs.
Warranty:
• ALL Parts: For period of 3 years from the date
of the original purchase.
Architectural Specifications:
ERV shall be of the ceiling mount type with no
less than 40 CFM on the exhaust port, 30 CFM
on the supply port, and no more than 0.8 sone
as tested in accordance with HVI 915 and 916
standards at 0.1 static pressure in inches water
gauge. Power consumption shall be no greater
than 23 watts. Apparent Sensible Effectiveness
for heating shall be no less than 66% at 30
CFM net air ow under 32°F (0°C) as tested in
accordance with CSA-C439. Total Recovery
Effectiveness for cooling shall be no less than
36% at 29 CFM net air ow under 95°F (35°C).
The supply port damper shall close below 20°F
(-7°C) to prevent freezing of the core. The motor
shall be totally enclosed, AC condenser type
engineered to run continuously. Power rating
shall be 120v/60Hz. Duct diameter shall be
no less than 4”. Fan shall be ASHRAE 62.2,
LEED, ENERGY STAR IAP, EarthCraft, California
Title-24, and WA Ventilation Code compliant.
ERV Core Technology:
• Indoor and outdoor air passes through
Panasonic’s capillary core technology.
This process tempers supply air while
transferring moisture and energy.
• Built in Frost Prevention Mode prevents the
core from freezing. Frost Prevention Mode is free
of interaction and operates without intervention.
FV-04VE1
Panasonic Home and Environment Company
Division of Panasonic Corporation of North America
One Panasonic Way
Secaucus, NJ 07094
www.panasonic.com/building
As of date 4/11
For complete Installation Instructions visit www.panasonic.com/building
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
VF11144SS
Performance: WhisperComfort FV-04VE1
Air Volume Setting
40 CFM 20 CFM 10 CFM
Static Pressure in inches w. g.
0.1 0.1 0.1
Exhaust Air Volume (CFM)
40 20 10
Supply Air Volume (CFM)
30 20 10
Noise (sones)
0.8 <0.3 N/A
Power Consumption (watts)
23 21 17
Speed (RPM) 1479 1292 1095
Current (amps) 0.15 0.10 0.09
Power Rating (V/Hz) 120/60
Energy Performance: WhisperComfort FV-04VE1
Apparent Sensible Effectiveness for Heating
66% at 30 CFM and 32°F (0°C)
Total Recovery Efficiency for Cooling
36% at 29 CFM and 95°F (35°C)