Dimensions Guide

Specification Submittal Data / Panasonic Ventilation Fan
FV-05-11VK1
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
FV-05-11VK1
7-3/8"
4"
10-1/4"
10-1/4"
13"
13"
4" or 6" duct
Performance Curve 4" or 6" duct
Adjustable Airflow for
Maximum Performance
Description
Customizable Ventilation Fan shall be low sone ceiling mount rated for continuous
run. Fan shall be ENERGY STAR
®
rated and certified by the Home Ventilating Institute
(HVI). Evaluated by Underwriters Laboratories and conform to both UL and cUL safety
standards.
Motor/Blower:
• Enclosed DC brushless motor technology rated for continuous run.
• Fan ventilation rates shall be manually adjustable for 50-80-110 CFM.
• Power rating shall be 120 volts and 60 Hz.
• Fan shall be UL listed for tub/shower enclosure when used with a GFCI protected
circuit and used in insulated ceiling (TYPE I.C.).
• Fan equipped with a thermal cutoff fuse
• Removable, permanently lubricated, plug–in motor.
Housing:
• Rust proof paint, galvanized steel body.
• Integrated dual 4" or 6" diameter duct adapter.
• Built-in metal flange provides blocking for penetrations through drywall as an Air
Barrier, and assists with the decrease in leakage in the Building Envelope during
blower door testing.
• Built in backdraft damper.
• Articulating and expandable installation bracket up to 24".
Grille:
• Attractive design using Poly Pro material.
• Attaches directly to housing with torsion springs.
• Includes a motion sensor cap for use as a cover when motion sensor
Plug ’n Play™ module has not been selected.
Warranty:
• ALL Parts: 3 Years from original purchase date.
DC Motor: 6 Years from original purchase date.
Architectural Specifications:
Customizable Ventilation Fan shall be ceiling mount, ENERGY STAR
®
rated type with
built-in speed selector. Select from 50/80/110 CFM and no more than <0.3 sone as
certified by the Home Ventilating Institute (HVI) at 0.1 w.g. with no less than 53/82/113
CFM and no more than 0.3/0.4/0.8 sones at .25 w.g. Power Consumption shall be
no greater than 3.5/5.5/9.8 watts at 0.1 w.g. and 15.1/15.3/11.5 watts at 0.25 w.g.
ENERGY STAR
®
rated with efficiency of no less than 15.1/15.3/11.5 CFM/watt at
0.1 w.g. and than 8.1/8.4/7.2 CFM/watt at 0.25 w.g. The motor shall be enclosed
with brushless DC motor engineered to run continuously. DC motor speed shall
automatically increase when the fan senses static pressure to maintain selected CFM.
Power rating shall be 120v/60Hz. Duct diameter shall be no less than 4", inclusive
of an integrated dual 4" or 6" duct adapter. Plug 'N Play™ modules provide up
to three additional features. Select from Multi-Speed with Time Delay, Condensation
Sensor, LED Night Light and Motion Sensor. Fan shall be UL and cUL listed for tub/
shower enclosure when used with a GFCI protected circuit. Fan can be used to comply
with ASHRAE 62.2, LEED, ENERGY STAR
®
IAP, EarthCraft, California Title-24 and WA
Ventilation Code.
DC Motor Technology:
When fan senses static pressure, its speed is automatically increased to
ensure that the desired CFM is not compromised, which allows the fan
to perform as rated.