Instructions / Assembly

PLEASE
READ
PRIOR
BEFORE
INSTALLATION
[For
model :
FV-081
OVSS1]
Spot
and
continuous
ventilation:
This
product
is
designed
to
run continuously ensuring a
healthy environment
at
low
airflow levels 24 hours a day.
By
utilizing the CustomVent Multi-
speed module the product
is
built
to
run continuously at a pre-set lower level (0, 30, 40, 50,
60, 70
CFM).
The
setting
is
dependent on the
size
of
the house and the individual wishes
of
the homeowner. It
is
crucial
that
the installer pre-set the lower setting during the
installation.
Please
refer
to
the chart below and the switch indication on page
6.
CustomVent Multi-speed module (Lower setting).
ASH
RAE
62.2-2010
(sq.feet)
Two Bedrooms Three Bedrooms Four Bedrooms
Five
Bedrooms
<1,000 33
40
48
55
1,500
38
45 53 60
2,000
43
50
58 65
2,500
48
55 63 70
3,000 53 60
68
75
3,500 58 65
73 80
4,000
63
70 78 85
4,500 68 75
83
90
5,000
73
80 88 95
5,500
78
85 93 100
6,000 83 90
98
105
6,500
88
95 103 110
7,000 93 100 108
-
This
product
is
also built
to
take care
of
the homeowner's spot ventilation needs when the
room
is
occupied and kicks up
to
a maximum level
of
100
CFM
when control switch
is
turned
on.
INSTALLATION I
{JOIST
MOUNTING)
1.Before installation, please remove the tape
which protects damper during shipping
and accessory screws from duct adaptor
and the tape which fixes condensation
sensor (FV-051
OVSC1
only), then check
that
the damper
can
open and close
smoothly. (Fig.1)
Note:
Please
remove the tape on damper
according
to
the direction
of
arrow
in
Fig.1, otherwise the damper may
be
pulled out.
2.0pen
one knock-out hole on junction box.
(Fig.2)
Note:
There are
two
knock-out holes, please
open one which
is
convient
for
wiring.
Tape
Accessory
screws
Condensation sensor
(FV-051
OVSC1
only)
Fig.1
Fig.2
~~~~~~~~~~~~~~~~~7