Specification

Specification Submittal Data / Panasonic Precision Spot
Ventilation Fan/Light with Dual Sensor Technology
FV-0511VQCL1
FV-0511VQCL1
4″or 6″Duct
7-3/8
4
10 -1 /4
13
10 -1 /4
13
4" or 6" duct
Description
Ventilating fan/light shall be low noise ceiling mount
type rated for continuous operation. Fan/light shall
be ENERGY STAR
®
rated and certified by the
Home Ventilating Institute (HVI). Evaluated by the
Underwriters Laboratories and conform to both UL
and cUL standards.
Motor/Blower:
• Enclosed brushless ECM motor technology
rated for continuous run.
• Fan ventilation rates shall be manually
adjustable for 50-80-110 CFM.
• Power rating shall be 120 volts and 60 Hz.
• Fan shall be UL and cUL listed for tub/shower
enclosure when GFCI protected and used in
insulated ceiling (TYPE I.C.).
• Motor equipped with thermal–cutoff fuse.
Removable with permanently lubricated plug-in motor.
Housing:
26 gauge Zinc-Aluminum-Magnesium (ZAM) housing.
• Integrated dual 4” or 6” diameter duct adapter.
• Built-in damper reduces back drafting and helps
with blower door testing.
• Built-in metal flange provides blocking for
penetrations through drywall as an Air Barrier,
and assists with the decrease in leakage in the
Building Envelope during blower door testing.
• Articulating and expandable installation bracket
up to 24”.
Ceiling Radiation Damper:
• WhisperSense DC is UL listed for use with the
Panasonic Ceiling Radiation Damper (Model #:
PC-RD05C5, sold separately).
Grille:
• Attractive design using Poly Pro material.
• Attaches directly to housing with torsion springs
Warranty:
• ECM Motor: 6 Years from original purchase date.
• LED Panel: 5 Years from original purchase date.
• ALL Parts: 3 Years from original purchase date.
Architectural Specifications:
Ventilation fan/light shall be UL and cUL listed for
ceiling mount and tub/shower enclosure
when GFCI protected. Fan/light shall also be
ENERGY STAR
®
certified, with a built-in speed
selector. Choose from 50-80-110 CFM and no
more than <0.3/<0.3/<0.4 sone as certified
by the Home Ventilating Institute (HVI) at 0.1 static
pressure in inches water gauge (w.g.)
with no less than 50-80-110 CFM and no more
than 0.4/0.6/0.9 sone as certified by HVI
at 0.25 w.g. Power Consumption shall be no
greater than 3.9/6.0/10.9 watts at 0.1 w.g. and
7.1/11.0/16.1 watts at 0.25 w.g., with efficiency of
no less than 14.1/13.7/10.3 CFM/watt at 0.1
w.g. and 7.8/7.7/7.0 CFM/watt at 0.25 w.g. The
motor shall be totally enclosed with a brushless
ECM motor engineered to run continuously. ECM
motor speed shall automatically increase
when the fan senses static pressure to maintain
selected CFM. Power rating shall be 120V/60Hz.
Duct diameter shall be no less than 4”, inclusive
of an integrated dual 4” or 6” duct adapter. Dual
motion and humidity sensors with adjustable
delay off timer that can be set from 30 seconds
to 60 minutes. Humidity sensor is the rapid rise in
relative humidity (RH) type with user-adjusted set
points between ~30% to ~80% RH. Fan/light shall
be UL and cUL listed for tub/shower enclosure
when GFCI protected. Lamp shall be of the LED
dimmable type and be no less than (1) 10W,
ENERGY STAR
®
2.0 certified, JA-8 compliant
for CA Title 24,
LED chip panel that maintains
50,000 hours rated average life and incorporates
a <1W LED night light. Fan/Light shall be used
to comply with ASHRAE 62.2, LEED, ENERGY
STAR
®
IAP, EarthCraft, California Title-24, WA
Ventilation Code and CALGreen.
(1) 10 Watt Dimmable LED chip panel/3000
Kelvin Warm White/90CRI/700 lumens/70 LPW/
ENERGY STAR 2.0 certified/JA-8 compliant for
CA Title 24/50,000 hours rated average life /<1W
LED night light.
L
O
N
G
L
I
F
E
T
E
C
H
N
O
L
O
G
Y
E
N
E
R
G
Y
S
A
V
I
N
G
E
C
O
F
R
I
E
N
D
L
Y
Panasonic Eco Solutions North America
Eco Products Division
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
VF16549SS0517
Specifications: WhisperSense DC FV-0511VQCL1
4" 4" 4"
Ventilation Fan
Characteristics
(HVI Certied
Data)
Static Pressure in inches w.g.
0.1 0.25 0.1 0.25 0.1 0.25
Air Volume (CFM)
110 110 80 83 50 50
Noise (sones)
0.4 0.9 <0.3 0.6 <0.3 0.4
Power Consumption (watts)
10.9 16.1 6.0 11.0 3.9 7.1
Energy Efciency (CFM/Watt)
10.3 7.0 13.7 7.7 14.1 7.8
Speed (RPM)
1016 1268 867 1185 768 1097
Current (amps)
0.18 0.26 0.11 0.19 0.07 0.12
MAX. Current (amps) 0.30
Power Rating (V/Hz) 120/60
ENERGY STAR rated
Yes
0.25=Installed Performance
ECM Motor Technology
When the fan senses static pressure, its speed is automatically increased to ensure
that the desired CFM is not compromised, which allows the fan to perform as rated.
FV-0511VQCL1
Light:
Performance Curve 4" Duct
Static Pressure (inch w.g.)
Airflow (CFM)
FV-0511VQCL1
110CFM
80CFM
50CFM
4" 20ft duct
4" 40ft duct
4" 60ft duct
4" 80ft duct
4" 100ft duct
0.00
0.10
0.20
0.30
0.40
0.50
0.60
0.70
0 10 20 30 40 50 60 70 80 90 100 110 120

Summary of content (1 pages)