Manual

14
MAINTENANCE II (REPLACEMENT OF LAMP) CONTINUEDMAINTENANCE II (REPLACEMENT OF LAMP) CONTINUED
Fig.27
3. Change the fluorescent lamps (Panasonic FDS
18E27/4,18 W or FDS18E35/4, 18 W or FDS18E42/4,
18 W ) or the 4 W night lamp, connect the connector
or connector and replace the grille. (Fig.27)
II
III
1. Remove grille. (Squeeze mounting spring and pull
down) (Fig.22 of page 13)
2. Disconnect connector or connector from
lighting unit. (Fig.26)
II III
Warning Concerning Removal of Covers.
The unit should be serviced by qualified technicians only. No service information is provided for customers.
Your product is designed and manufactured to ensure a minimum of maintenance. However, should your
unit ever require service, a nationwide system of factory service centers and AUTHORIZED INDEPENDENT
SERVICE CENTERS is maintained to support your product's warranty.
(In the U.S.A.,call 1-866-292-7292 to Customer call Center.)
P ODUCT SE VICERRP ODUCT SE VICERR
Loose fill or batt insulation can be placed
directly over the fan housing in the attic.
Panasonic fans and fan/light combination
units do not create excessive heat that is
a common problem with recessed light
fixtures or some competitors' fan/light
combinations. Our efficient, cool-running
motors and our fluorescent lamps do not
create enough ambient heat to be subjected
to these limitations.
Proper insulate the area around the fan to
minimize building heat loss and gain. (Fig.28)
Fig.28
Dryer-hood type vent with
backdraft flap (s).
Caulk termination to duct.
2-3 ft straight run before elbow.
In attic installation,
caulk box to drywall.
Short piece of flexible duct
helps alignment and absorbs
sound. Clamps plus tape at
all flex joints.
Foil tape tightly covers all metal
duct joints (glue PVC joints).
Insulation
P ACTICAL GUIDE TO INSTALL ATIONRP ACTICAL GUIDE TO INSTALL ATIONR
Fig.26
4 W Night Lamp
Fluorescent lamps
Plug connector III
Plug connector II
Receptacle II
Receptacle III