FV-08VSL3 FV-10VSL3 2-3 4 4 4 5 5 (Joist Mounting) (Wall Mounting) 6-7 8 (Cleaning) 9 (Replacement of lamp) 10 11 11
For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed. WARNING Denotes a potential hazard that could result in serious injury or death.
WARNING USA only: This product has a fluorescent lamp that contains mercury. Disposal may be regulated in your community due to environmental considerations. For disposal or recycling information, please contact your local authorities or visit Panasonic website: http://www.panasonic.com/environmental or call 1-888-769-0149. Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40.
These Panasonic ventilating fan models are listed by UL under UL file No. E78414. The lighting unit is an energy-saving, lighting device that uses two 13W fluorescent lamps and produces almost the same illumination as a standard 100W incandescent lamp. FCC Note: This equipment contains two self-ballast fluorescent lamp and is in compliance with Part 18 of the FCC Rules as consumer RF lighting device.
2 7/8 (73) 10 1/4 (260) 3 3/8 (85) 3 3/4 (94) Fan body Junction box Fluorescent lamp (Self-ballasted) (LIGHT) Black Live White Neutral Power supply AC120V 60Hz Black Live Power supply AC120V 60Hz Night lamp (N.
1. Before installation, remove the tape from damper and adaptor, and check that the damper can open and close smoothly. Then remove the accessory screws from suspension bracket. (Fig.1) Tape Damper 2. Fix the flange of frame to joist by 2 long screws(ST4.2x30), and fix the suspension bracket to joist by 2 long screws(ST4.2x30). (Fig.2) Accessory screws Tape Adaptor Suspension bracket Fig.1 2 Long screws (ST4.2x30) 3.
6. Finish ceiling work. Ceiling hole should be aligned with the inside edge of the flange. (Fig.4) 7. Remove the tape from mounting springs, lead wire, and night lamp before installation as shown below. Tape After finishing the ceiling job, fill gap between flange and ceiling with caulk or other sealant to prevent air leakage. Fig.4 Lead wire Tape Night lamp 8. Remove the screw as shown in step 1 of Fig.5. Remove the light cover as shown in step 2 of Fig.5. Fig.5 9.
WALL 1. Before installation, remove the tape from damper and adaptor, and check that the damper can open and close smoothly. Then remove the accessory screws from suspension bracket. (Fig.1of page 6) 2. Fix the flange of frame to stud by 2 long screws(ST4.2x30), and fix the suspension bracket to stud by 2 long screws(ST4.2x30). (Fig.10) Stud 4 Long screws (ST4.0 x 30) Fig.10 CAUTION The adaptor of product must be installed upward.(Fig.10) 10 1/2 (266) Wall 3.
WARNING CAUTION Fig.13 1. Clean grille.(Don’t put into water over Use non-abrasive kitchen detergent, wipe dry with clean cloth.)(Fig.13) 2. The grille should be dry after cleaning. 3. Remove grille by pulling down the mounting spring in the right side of “Panasonic” logo. Remove dust and dirt from fan body using a vacuum cleaner. (Fig.14) Fig.14 4. Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with clean cloth. (Fig.15) 5. Replace grille. Fig.
WARNING Disconnect power source before working on unit. This is a pin type lamp base and the lamp’s glass is fragile. To remove, pull out carefully. Fig.16 4W night lamp has threade d base. Remove by turning counterclockwise. Make sure the temperature of lens and lighting unit has cooled down before maintenance(cleaning) or replacement of lamp. Mounting spring CAUTION Remove dust and dirt from light cover and lens, before replace the lamps. Lighting unit Fig.17 1.
Properly insulate the area around the fan to minimize building heat loss and gain. (Fig.21) Loose fill or batt insulation can be placed directly over the fan housing in the attic. Our fans and fan/light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor’s fan/light combination. Our efficient, cool-running motors and our fluorescent lamps do not create enough ambient heat to be subjected to these limitations. Fig.21 FV-08VSL3 1.