Motor/Blower:
Two (2) enclosed DC brushless motors rated
• ERV shall have Hi/Lo Speed Occupant
Controlled Boost Capability
for continuous run.
ERV Supply and Exhaust ventilation rates
shall be manually adjustable for 50-60-70-80-
90-100 CFM.
Power rating shall be 120 volts and 60 Hz.
Motor equipped with thermal cut-off fuse
control.
Removable, permanently lubricated, plug–in
motor.
Housing:
22 gauge galvanized steel body.
Four 4" or 6" intake and exhaust ducts.
Built in damper on Outdoor Air (OA) closes
during defrost function when the outdoor
temperature is too cold.
Filters on supply and exhaust air extend the
life of the ERV core.
(4) Pressur
Pre-drilled mounting bracket can
accommodate 16", 19", or 24" on center.
Maintenance:
MER
FL0810VE1) and optional MERV 13 (FV-
FL1310VE1) replacements available.
check and maintenance.
Warranty:
DC Motors: 6 years from original purchase
date
All Parts: 3 Years from original purchase date.
FV-10VE2
Temperate Climate ERV
Panasonic Life Solutions Company of America
IAQ Division
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
IAQ19203ST
FV-10VE2
Four 4" or 6" ducts
Energy Recovery Ventilator
Optional Exterior Wall Cap (see next page)
DC Motor Technology
When the ERV senses static pressure, its
speed is automatically increased to ensure that
the desired CFM is not compromised.
2 8 -1/ 2
'
8 -7/8 '
2 3 '
4 ' D ia
6 ' D ia
6 ' D ia
4 ' D ia
1 3 '
Ceiling or wall mount Cold Climate Energy
Recovery Ventilator (ERV) provides a tempered
air supply, humidity control, and a balanced
amount of exhaust to help maintain balanced,
positive or negative pressure throughout the
home. The Panasonic Intelli-Balance ERV is
engineered for use in any North America
climate zone. Version 2 includes new Hi/Lo
Occupant Controlled Boost Capability. Built-in
ASHRAE 62.2 Timing function helps ensure
code compliance.
ERV shall be ceiling or wall mount type with
built-in speed selectors for both Supply and
Exhaust air. Select from 50/60/70/80/90/100
CFM. ERV shall have 100 Net CFM on the
exhaust ports and 100 Net CFM on the supply
ports as tested in accordance with HVI 915 and
916 standards at 0.1 static pressure in inches
water gauge. ERV shall have 100 Net CFM on
the exhaust ports and Net 100 CFM on the
supply ports at 0.4" w.g. static pressure. ERV
shall have Hi/Lo Speed Occupant Controlled
Boost Capability. Power consumption shall be
no greater than 81 watts at 0.1" w.g. and 100
watts at 0.4" w.g. static pressure. Apparent
Sensible Effectiveness for heating shall be no
less than 84% at 53 CFM net air flow under
32°F (0°C) as tested in accordance with
CSA-C439. Total Recovery Efficiency for cooling
shall be no less than 60% at 49 CFM net air flow
under 95°F (35°C). The supply port damper shall
close when outdoor temperatures are < 14°F
(-10°C) to prevent freezing of the core. The (2)
motors shall be totally enclosed DC brushless
motors rated for continuous run. DC motor
speed shall automatically increase when the fan
senses static pressure to maintain selected
CFM. ERV shall incorporate an ASHRAE 62.2
Intermittent Timing function for code
compliance. ERV shall have standby/low speed
to high speed control airflow capability as
desired by occupant. Power rating shall be
120v/60Hz. Duct diameters shall be no less than
4". ERV can be used to comply with ASHRAE
62.2, LEED, IAP, California Title-24, and WA
Energy Code
r7
ERV Core Technology:
Indoor and outdoor air passes through
Panasonic’s capillary core technology. This
process tempers supply air while transferring
moisture and energy.
Built in Frost Prevention Mode prevents the
core from freezing. Frost Prevention Mode
is intuitive and operates without homeowner
intervention.
Core material permeated with anti-mold
treatment.