Model No.
For Your Safety To reduce the risk of injury, loss of life, electric shock, fire, malfunction, and damage to equipment or property, always observe the following safety precautions. Explanation of symbol word panels The following symbol word panels are used to classify and describe the level of hazard, injury, and property damage caused when the denotation is disregarded and improper use is performed. WARNING Denotes a potential hazard that could result in serious injury or death.
WARNING Canada only: Not to be installed in a ceiling thermally insulated to a value greater than R40. Do not disassemble the unit for reconstruction. It may cause fire or electric shock. When this product is no longer being operated, please remove the product to prevent the possibility of falling. Ceiling joist must be subjected to static load more than five times the weight of the product. Do not install with a method which is not approved in the instructions.
PLEASE READ PRIOR TO INSTALLING THIS FAN Spot and Continuous Ventilation: These fans are designed to run continuously ensuring a healthy environment at low CFM levels 24 hours a day. By utilizing the optional CustomVent Multi-Speed module the fans are built to run continuously at a pre-set lower level (FV-05-11VKS1 and FV-05-11VK1: 0, 30, 40, 50, 60, 70, 80, 90, 100 CFM; FV-11-15VK1: 0, 50, 60, 70, 80, 90, 100, 110, 120 CFM).
SUPPLIED ACCESSORIES Quantity Part name 1 Warranty sheet 1 Flex-Z FastTM bracket 1 Tapping screw (ST4.2X20) 4 Installation instructions 2 Self-drilling screw 4 Part name Appearance Grille Quantity Appearance DIMENSIONS Unit: inches (mm) 7/8 (22.5) 1 (26) 4 5/8 (116) 3 1/2 (88) 3 1/4 (81) 5 7/8 (148) 3 7/8 (98) 5 7/8 (148) FV-11-15VK1 13 (330) FV-05-11VK1 FV-11-15VK1 10 1/4 (260) 12 1/8 (307) 10 6 3/8 (163) 12 FV-11-15VK1 7 3/8 (190) 11 11 FV-05-11VKS1 No.
FEATURE [For models of: FV-05-11VKS1, FV-05-11VK1, FV-11-15VK1.] The WhisperGreen Select Line of ventilation fans employs innovative, state-of-the-art technologies that provide a number of customizable unique features that lead to improved indoor air quality. Please read the installation manual first in order to realize the benefits of this customizable, modular fan.
INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED PLUG ‘N PLAY Modular Component Accessories Sold Separately, Not Included With Base Model Fan FV-CSVK1 Condensation Sensor module turns the base fan on or boosts to higher speed when humidity is detected when used in combination with the FV-VS15VK1. The Condensation Sensor works based on calculations from the Psychrometric Chart, or combination of Relative Humidity (RH) and Temperature.
INSTALLATION (PLUG ‘N PLAY FUNCTION DEVICES) You can purchase the specified Plug ‘N Play devices that are explained on page 6-7 and install them in positions , 2 and 3 . Position can only be used with Multi-Speed module (model FV-05-11VKS1 already have this control installed), position 2 and 3 can be used for any of the other optional control modules. 1. Remove the connector cover from position , 2 or 3 . 2.
INSTALLATION (NEW CONSTRUCTION) CONTINUED 7. Refer to wiring diagram on page 5. Follow all the local electrical safety codes as well as the National Electrical Code (NEC). Using UL approved wire nuts, connect house power wires to ventilating fan wires. (Fig.5) FV-05-11VKS1 FV-05-11VK1 FV-11-15VK1 Conduit Wire nut Junction box CAUTION Mount junction box cover carefully so that lead wires are not pinched. 8.
INSTALLATION (NEW CONSTRUCTION) CONTINUED 13. Adjust Pick-A-Flow switch; if used, adjust the FV-VS15VK1 Multi-Speed module. (Fig.10) Refer to indication on page 6. Ceiling Grille 14. Insert the other mounting spring into the slot as shown and mount grille to fan body. (Fig.11) CAUTION Mount grille carefully so that lead wire is not pinched. Fig.10 Ceiling Mounting spring Gloves Fig.
WARNING Mounting spring Disconnect power source before working on unit. Grille Gloves Slot Fig.15 CAUTION Routine maintenance must be done every year. Please wear gloves during the cleaning work. Never use gasoline, benzene, thinner or any other such chemicals for cleaning the ventilating fan. Do not immerse motor in water when cleaning. Do not soak resin parts in water over 140°F (60°C). 1. Remove grille by pulling down one mounting spring (Fig.15), then pull down the other.
PRACTICAL GUIDE TO INSTALLATION Properly insulate the area around the fan to minimize building heat loss and gain. (Fig.20) Loose fill or batt insulation can be placed directly over the fan housing in the attic. Our fans and fan/light combination units do not create excessive heat that is a common problem with recessed light fixtures or some competitor’s fan/light combination. Our efficient, cool-running motors and our LED lighting unit do not create enough ambient heat to be subjected to these limitations.