Submittal Sheet

Specification Submittal Data / Panasonic Ventilation Fan
Description
Ventilating fan shall be low noise ceiling mount
type rated for continuous run. Fan shall be
certified by the Home Ventilating Institute (HVI).
Fan shall include energy efficient compact
fluorescent lighting and night-light. Heating
element shall be included. Evaluated by
Underwriters Laboratories and conform to
both UL and cUL safety standards. Fan is not
intended for installation over a tub/ shower
enclosure.
Motor/Blower:
• Four–pole totally enclosed condenser motor
rated for continuous run.
• Power rating shall be 120 volts and
60 Hz.
• Motor equipped with thermal–cutoff fuse.
• Permanently lubricated plug–in motor.
Housing:
• Rust proof paint, galvanized steel body.
• 4" diameter duct adapter.
• Built-in backdraft damper.
Grille:
• Attractive design using ABS material.
• Attaches directly to housing with torsion
springs.
Light:
• Two 18-Watt, 3500 Kelvin
quick start compact
fluorescent lamps
included.
• One 4-Watt night–light
included.
Heater:
• Tubular steel sheathed
heating element.
Nichrome wire with
magnesium oxide for
optimal heat transfer and
electrical insulation at
elevated temperatures.
• 90 CFM super quiet, energy efcient blower
motor.
• Quick 1-minute warm-up.
Warranty:
• 3-Year limited warranty on all parts. Compact
Fluorescent Lamp (CFL): 10,000 hours. No
warranty on night-light.
Architectural Specifications:
Ventilation fan, heater, light and night-light
combination shall be ceiling mount, with no less
than 110 CFM and no more than 0.7 sone as
certied by HVI at .1 static pressure in inches
water gauge (w.g.) with no less than 89 CFM
and no more than 1.0 sone at .25 w.g. Power
consumption shall be no greater than 30.6
Watts at .1 w.g. and 30.5 Watts at .25 w.g. With
efciency of no less than 3.6 CFM/Watt at .1
w.g. and 2.9 CFM/Watt at .25 w.g. The motor
shall be totally enclosed, 4 pole condenser type
engineered to run continuously. Power rating
shall be 120v/60Hz. Duct diameter shall be no
less than 4". Fan is not intended for installation
over a tub/shower enclosure. Fan shall be
ASHRAE 62.2, LEED, EarthCraft, California
Title-24, and WA Ventilation Code compliant.
Lamps utilize no less than two 18-Watt energy
efcient, compact uorescent lamps while
incorporating a high efficiency electronic
ballast. Night-light shall be included. Heating
element shall be Nichrome wire in tubular steel
sheath construction with magnesium oxide for
optimal heat transfer. Heating element power
consumption shall be no less than 1400 watts.
Heating feature shall include a 90 CFM blower
fan with energy efficient condenser type motor
with quick 1-minute warm-up.
FV-11VHL2
Panasonic Home and Environment Company
Division of Panasonic Corporation of North America
One Panasonic Way
Secaucus, NJ 07094
www.panasonic.com/building
For complete Installation Instructions visit www.panasonic.com/building
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
14-1/2 or 22-1/2”
4”
16”
7-3/4”
11-1/2”
14-1/2”
14-1/8”
18-1/8”
VF11144SS-L
FV-11VHL2
Specications:
WhisperWarm FV-11VHL2
Static Pressure in inches w.g.
0.1 0.25
Air Volume (CFM)
110 89
Noise (sones)
0.7 1.0
Power Consumption (watts)
30.6 30.5
Energy Efficiency (CFM/Watt)
3.6 2.9
Speed (RPM)
812 956
Heating Element (Watts) 1400
Blower Fan (Watts) 25
Blower Fan (CFM) 90
Fan/Heater/Light/Night–Light (Amps)
12.5
FV-11VHL2

Summary of content (1 pages)