Sell Sheet
ASHRAE 62.2 INTERMITTENT TIMING FUNCTION
The adjustable Minutes Per Hour (Min/Hr) timer allows the user to set the number
of minutes per hour the ERV should run. This gives scalability of air flow relative to
property size; from the smallest multi-family to larger single family applications.This
ensures consistent and controlled ventilation throughout the day for compliance with
ASHRAE 62.2. Factory default setting is 60 Min/Hr.
FILTERS & MAINTENANCE
Intelli-Balance™ 200 has two filters that clean the exhaust and supply air before
passing through the ERV core, extending the life of the core. A hinged access panel
allows for quick and easy maintenance and filter checks. A convenient indicator light
and unobtrusive alarm signal from the access panel, and notification on the LCD wall
control, will help inform the homeowner when it’s time to check and clean the filters.
Both filters should be vacuumed with a soft brush attachment every 2-3 months or as
needed, and the supply air filter should be inspected every 90 days and replaced every
6 months to maintain the ERV’s peak performance.
CAPILLARY CORE
Indoor and outdoor air pass through Panasonic’s patented capillary core designed
to transfer heat and moisture. This process tempers supply air while balancing
moisture levels inside to outside. The core’s high latent energy (moisture) transfer
makes Intelli-Balance 200 ideal for use in most climate zones, as it helps expel
moisture during incidences of high relative humidity (RH) and helps return moisture
back inside during the winter for a healthier, more comfortable living environment.
Core material permeated with anti-mold treatment to help prevent mold in the home.
WHOLE HOUSE ERV
Intelli-Balance™ 200 is a ceiling, floor or wall mount Energy Recovery Ventilator
(ERV) that’s ideal for meeting whole house ventilation requirements under ASHRAE
62.2. Intelli-Balance™ 200 is also an ideal choice when partnered with mini-splits or
VRF Heat Pumps for fresh, balanced air with energy recovery which makes it a very
affordable, cost-effective IAQ solution.
Ideal for: Single Family Homes (≤ 7500 sq. ft., up to 7 bedrooms) / Condominiums /
Apartments / Housing Authority Properties / Hotels / Studio apartments (based on
ASHRAE 62.2 2010 standard.)
ASHRAE 62.2 2010 AND 2013 STANDARD
The American Society of Heating, Refrigerating and Air Conditioning Engineers
(ASHRAE) set a standard for whole house ventilation, requiring continuous
mechanical ventilation be 7.5 CFM per bedroom (master bedroom X 2) plus 1 CFM
per 100 square feet, with sones not to exceed 1.0. ASHRAE 62.2-2013 requires a
ventilation rate of 7.5 CFM per person plus 3 CFM per 100 square feet. Please check
with your local jurisdiction to determine which ventilation standard you should
follow. Panasonic Intelli-Balance
™
200 ERV is an affordable, efficient way to meet the
ASHRAE 62.2 standard.
OPERATION
The Intelli-Balance
™
200 can operate in areas where temperatures can drop as low
as -22°F (-30°C). The Intelli-Balance™ 200 features a defrost cycle function that
activates when outdoor temperature drops to 14°F, (-10°C). This helps protect the
capillary core from frost build up, and maintain effective operation.
Supply Air Filter (SA) MERV 13 filter (included)
Return Air Filter
Capillary Core
Accessories (Sold Separately):
FV-FL1320VE1: MERV 13 Optional Replacement Filter
FV-FL0820VE1: MERV 8 Optional Replacement Filter
FV-FLHP20VE1: HEPA Optional Replacement Filter