Specification Sheet

/ Panasonic ERV
FV-20VEC1
Panasonic Life Solutions Company of America
IAQ Division
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
IAQ21056ST
Canada and is ENERGY STAR
®
FV-20VEC1
6" ducts
Energy Recovery Ventilator
ECM Motor Technology
Description
Ceiling, wall or or floor mount Energy Recovery
Ventilator (ERV) provides a tempered air supply,
humidity control, and a balanced amount of
exhaust to help maintain balanced, positive or
negative pressure throughout the home. The
Panasonic Intelli-Balance ERV is engineered for use
in any North America climate zone. Incorporates an
Occupant Controlled Boost Capability. Built-in
ASHRAE 62.2 Timing function helps ensure
code compliance.
Motor/Blower:
Occupant Controlled Boost Capability
• Two (2) enclosed ECM brushless motors rated
for continuous run.
• ERV Supply and Exhaust ventilation rates
shall be manually adjustable for
60-80-100-120-140-160-180-200 CFM.
• Power rating shall be 120 volts and 60 Hz.
• Motor equipped with thermal cut-off fuse control.
• Removable, permanently lubricated, plug–in
motor.
Housing:
• 22 gauge powder coated steel body.
• Four 6" intake and exhaust ducts.
• Adjustable supply and return air adapters provide
greater installation flexibility
• Built in dampers on outside exhaust air and
supply ducts for defrost and recirculation cycling.
• Filters on supply and exhaust air extend the
life of the ERV core.
• (4) Pressure ports allow for easy airflow
documentation.
• Pre-drilled mounting bracket can
accommodate 16", 19", or 24" stud bays.
Maintenance:
• MERV 13 filter included; MERV 13
(FV-FL1320VE1), MERV 8 (FV-FL0820VE1) and
HEPA (FV-FLHP20VE1) filter replacements
available.
• Unobtrusive alarm notifies owner for filter
check and maintenance.
Warranty:
• ECM Motors: 6 years from original purchase date
• All Parts: 3 Years from original purchase date.
Architectural Specications:
ERV shall be ceiling, wall or floor mount type with
built-in speed selectors for both Supply and
Exhaust air. Select from 60-80-100-120-140-
160-180-200 CFM. ERV shall have 200 Net CFM
on the exhaust ports and 200 Net CFM on the
supply ports as tested in accordance with
CSA-C439 standards at 0.4 static pressure in
inches water gauge. ERV shall have Occupant
Controlled Boost Capability. Power consumption
shall be no greater than 129 watts at 0.4" w.g.
static pressure. Apparent Sensible Effectiveness for
heating shall be no less than 86% at 67 CFM net air
flow at 32°F (0°C). Sensible Recovery Efficiency for
heating shall be no less than 67% at 66 CFM net air
flow at -13°F (-25°C). Total Recovery Efficiency for
cooling shall be no less than 61% at 135 CFM net
air flow at 95°F (35°C). The defrost cycle function
shall activate when outdoor temperatures drop to
14°F (-10°C). The (2) motors shall be totally
enclosed ECM brushless motors rated for
continuous run. ECM motor speed shall
automatically increase when the fan senses static
pressure to maintain selected CFM. ERV shall
incorporate an ASHRAE 62.2 intermittent and
continuous timing function for code compliance.
Power rating shall be 120v/60Hz. Duct diameters
shall be no less than 6". ERV must include
adjustable vertical to horizontal supply and return
air adapters. Can be used to comply with ASHRAE
62.2, Ontario, ENERGY STAR
®
* and Novoclimat
requirements; LEED, IAP, California Title-24, and
WA Energy Code Credits.
ERV Core Technology:
• Indoor and outdoor air passes through
Panasonic’s capillary core technology. This
process tempers supply air while transferring
moisture and energy.
• Built in Frost Prevention Mode prevents the
core from freezing. Frost Prevention Mode
is intuitive and operates without
homeowner intervention.
• Core material permeated with anti-mold
treatment.
When the ERV senses static pressure, its
speed is automatically increased to ensure
that the desired CFM is not compromised.
6''Dia
6''Dia
6''Dia
6''Dia
27-3/4
9
-1/2
2
2
-7
/8
3
0
-3
/4
19-1/2
9-7/8
2
1
-5
/8
r4

Summary of content (2 pages)