2012 Ventilation Fans Panasonic Home and Environment Company Division of Panasonic Corporation of North America Executive Offices: One Panasonic Way Secaucus, NJ 07094 (201) 348-7000 For Distributor Order Information PHONE: 866-292-7299 FAX: 888-553-0723 www.panasonic.com/building ventfans@us.panasonic.com Design and specifications subject to change without notice.
High-performance ventilation solutions Panasonic is the premier manufacturer of powerful, The idea of delivering a breath of fresh air to our energy-efficient ventilation fans that quietly exhaust customers is consistent with a simple mission unhealthy, unpleasant or moist air from your home statement eloquently articulated by our founder or business.
Table of Contents Why is Ventilation Necessary?____________________________________________________ 6-7 Panasonic Ventilation Fan Benefits_______________________________________________8-9 Fans with Built-in Controls______________________________________________________ 10-11 Single Speed Fans (On/Off)____________________________________________________ 12-13 Fan/Lights with Built-in Controls________________________________________________ 14-15 Single Speed Fans with Lights_________________________________
Why is ventilation necessary? Today’s homes are designed and built Volatile Organic Compounds (VOCs) to improve energy efficiency. However, Volatile Organic Compounds are carbon- these airtight homes may actually cause based compounds that easily evaporate. health problems due to the build-up Formaldehyde and these types of gases of pollutants and uncirculated stale are released from building materials, air.
Panasonic Ventilation Fan Benefits Certified & Code Compliant Panasonic ventilation fans are certified by the Home Ventilating Institute (HVI) and ENERGY STAR® qualified, where guidelines exist. All models also comply with ASHRAE 62.2, the ventilation standard required by LEED for Homes, ENERGY STAR IAP, CalGreen, NAHB Green Building Standard, EarthCraft, Washington Ventilation Code and other building programs.
Fans with Built-in Controls WhisperGreen Key Benefits: • SmartFlow™ technology for optimal CFM output WhisperGreen FV-08VKS3 | FV-08VKM3 FV-13VKS3 | FV-13VKM3 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 0.
Single Speed Fans (On/Off) WhisperGreen Key Benefits: WhisperGreen • SmartFlow™ technology for optimal CFM output 7-2/5" Depth Characteristics FV-08VK3 Static pressure in inches w. g. 0.1 0.25 0.1 0.25 0.1 0.25 Air Volume (CFM) 50 54 80 79 110 112 • Detachable dual 4" or 6" duct adaptor included Noise (sones) <0.3 0.3 <0.3 0.4 0.3 0.8 Power Consumption (Watts) 4.3 7.5 7.0 11.0 11.5 16.2 Energy Efficiency (CFMs/Watt) 12.4 7.7 12.1 7.6 9.7 7.
Fan/Lights with Built-in Controls 7-2/5" Depth INCLUDES: One 32-Watt Panasonic CFL/3500 Kelvin/High CRI/2400 Lumens/ENERGY STAR® qualified/10,000 hours rated average life/equivalent to (2) 75-Watt incandescent lamp/ electronic ballast for flickerfree operation/plus 4-Watt night-light FV-08VKML3 80 CFM 4" or 6" Duct FV-08VKSL3 80 CFM 4" or 6" Duct FV-13VKML3 130 CFM 6" Duct FV-13VKSL3 130 CFM 6" Duct WhisperGreen-Lite Key Benefits: • SmartFlow™ technology for optimal CFM output • Built-in va
Single Speed Fans with Lights (On/Off) 7-2/5" Depth FV-08VKL3 80 CFM FV-11VKL3 110 CFM WhisperGreen-Lite Key Benefits: INCLUDES: One 32-Watt Panasonic CFL/3500 Kelvin/ High CRI/2400 Lumens/ENERGY STAR® qualified/10,000 hours rated average life/equivalent to (2) 75-Watt incandescent lamp/electronic ballast for flicker-free operation/plus 4-Watt night-light WhisperGreen-Lite • SmartFlow™ technology for optimal CFM output Static pressure in inches w. g. 0.1 0.25 0.1 0.
Specialty Fans WhisperWarm Key Benefits: FV-11VH2 110 CFM 4" Duct FV-11VHL2 110 CFM 4" Duct • Durable 1400 Watt stainless steel sheathed heating element FV-11VHL2 INCLUDES: Two 18-Watt Panasonic CFL/3500 Kelvin/High CRI/1200 Lumens each/ENERGY STAR® qualified/10,000 hours rated average life/equivalent to 100-Watt incandescent lamp/electronic ballast for flicker-free operation/plus 4-Watt night-light FV-20VQ3 190 CFM FV-30VQ3 290 CFM FV-40VQ3 380 CFM WhisperWarm • Thermal fuse protection on motor and 3
Accessories WhisperControl Condensation Sensor On/Off— FV-WCCS1-W (White), FV-WCCS1-A (Light Almond) On/Off/Light— FV-WCCS2-W (White), FV-WCCS2-A (Light Almond) WhisperControl Switches 1 Function Control FV-WCSW11-W (White) FV-WCSW11-A (Light Almond) WhisperControl Condensation Sensor Features & Benefits: • Humidity Control – Automatically turns on when relative humidity and temperature change is detected • • • • • • 30 minute countdown timer Manual On/Off Control Compatible with single-speed
Accessories WhisperControl Switches 3 Function Control FV-WCSW31-W (White) FV-WCSW31-A (Light Almond) WhisperControl Switches Features & Benefits: • Multi-switch combination saves space and adds convenience • Common feed shunted internally to all switches • Commercial grade • Includes matching wall plate • Elegant styling provides multiple controls in a single-gang wall box WhisperControl Switches 4 Function Control FV-WCSW41-W (White only) Designed for model FV-11VHL2 Heater/Fan/Light/Night-light Whi
AT S E R LL E A AT ST E A Ceiling Radiation Damper NI ST TIN I SOF CA LIFO G F IR E MAR SH E L Accessories R VI C File # 3225-1598:100 Radiation Damper Features: Fan Model approved for: • UL classification (UL standard 555C) for use in 1, 2 or 3 hour fire-rated floor/ceiling and roof/ceiling designs WhisperCeiling: FV-15VQ5, FV-11VQ5, FV-08VQ5, FV-05VQ5 WhisperFit: FV-11FV2, FV-08VF2, FV-05VF2 WhisperValue: FV-10VS1, FV-08VS1, FV-05VS1 • Available for 50 - 150 CFM fans PC-RD05C3 Fi
Fans with Built-in Controls —Performance Curves 4" Duct FV-13VKM3/S3 130/0 CFM 6" Duct Static Pressure(inch w.g.
0.25 40 Feet 0.20 60 Feet 0.20 100 Feet 0.00 20 40 60 80 Airflow(CFM) FV-05VF2 50 CFM 4" Duct 0.45 0.40 FV-05VF2 4" duct 0.35 0.30 20 Feet 0.25 40 Feet 0.20 60 Feet 0.15 80 Feet 0.10 100 Feet 20 40 0 50 0.60 20 Feet 0.50 40 Feet 0.40 60 Feet 0.30 80 Feet 0.20 100 Feet 100 Airflow(CFM) 0.50 4" Duct 20 Feet 0.40 40 Feet 0.
Single Speed Fans with Lights —Performance Curves 0.50 0.45 FV-05VFL2 3" duct 0.40 20 Feet 0.35 0.30 40 Feet 0.25 60 Feet 0.20 80 Feet 0.15 0.10 0.00 20 40 60 80 Airflow(CFM) Static Pressure(inch w.g.) FV-05VFL2 50 CFM 4" Duct 0.55 0.50 0.45 FV-05VFL2 4" duct 0.40 20 Feet 0.35 0.30 40 Feet 0.25 60 Feet 80 Feet 0.15 0.00 4" Duct 㻩㻹㻐㻔㻔㻹㻴㻯㻘 㻕㻓㻃㻩㼈㼈㼗 㻗㻓㻃㻩㼈㼈㼗 㻙㻓㻃㻩㼈㼈㼗 㻛㻓㻃㻩㼈㼈㼗 㻔㻓㻓㻃㻩㼈㼈㼗 㻓㻑㻗㻓 㻓㻑㻖㻓 Static Pressure(inch w.g.) 㻓㻑㻖㻓 Static Pressure(inch w.g.) Static Pressure(inch w.g.
Specialty Fans —Performance Curves 0.50 FV-11VH2 20 Feet 40 Feet 60 Feet 80 Feet 100 Feet 0.40 0.30 0.60 0.50 0.30 0.20 0.20 0.10 0.10 0.00 0.00 0 25 50 75 100 FV-11VHL2 20 Feet 40 Feet 60 Feet 80 Feet 100 Feet 0.40 125 Airflow(CFM) 0.80 0.70 0.60 FV-10NLF1 0.50 20 Feet 0.40 40 Feet 0.30 80 Feet 60 Feet 100 Feet 0.20 0 25 50 75 100 125 0.60 0.50 FV-20VQ3 20 Feet 0.40 40 Feet 60 Feet 0.30 Static Pressure(inch w.g.) Static Pressure(inch w.g.) 20 40 60 100 Feet 0.
Fans with Built-in Controls —Dimensional Drawings 4" or 6" Duct FV-08VKM3 4" or 6" Duct 6" duct FV-13VKM3 4"or 6" duct FV-08VKS3 4"or 3" duct 6" duct FV-13VKS3 Single Speed Fans —Dimensional Drawings 4"or 6" duct 6" duct 4"or 6" duct FV-05VK3/FV-08VK3/FV-11VK3 FV-05VQ5 / FV-08VQ5 / FV-11VQ5 FV-15VQ5 4" oval duct 4" duct 14-1/2" or 22-1/2” 3" 14-1/2 or 22-1/2” 4" 10-1/4" 3-1/16” 3-3/4” 14-1/2” 10-1/4" 8” 5/ 4- 5-5/8" 10-1/4” 10-1/4” 14-1/2" 13" FV-08VQC5 / FV-11VQC5 FV-05V
Fan/Lights with Built-In Controls — Dimensional Drawings 4"or 6" duct FV-08VKML3 4"or 6" duct 4"or 6" duct FV-08VKSL3 6" duct FV-13VKML3 6" duct FV-13VKSL3 Single Speed Fans with Lights — Dimensional Drawings 4"or 6" duct 4"or 6" duct 6" duct FV-08VQL5 / FV-11VQL5 FV-08VKL3 /FV-11VKL3 FV-15VQL5 4" oval duct 4" duct 3" 14-1/2" or 22-1/2” 14-1/2 or 22-1/2” 4" 8” 5/ 4- 3-1/16” 5-5/8” 3-3/4” 14-1/2” 14-1/2" 10-1/4” 10-1/4” 10-1/4” 10-1/4” 2-7/8” 13” FV-08VQCL5 / FV-11VQCL5 13
Specialty Fans —Dimensional Drawings 4" duct 4" duct 2 x 4" ducts 14-1/2 or 22-1/2” 4” 16” 7-3/4” 11-1/2” 14-1/2” 18-1/8” 14-1/8” FV-11VHL2 6" duct FV-20VQ3 / FV-30VQ3 FV-11VH2 FV-04VE1 Inlet grille and 4" duct adaptor height 3-1/2" Inlet grille and 6" duct adaptor height 5" 6" duct FV-40VQ3 WhisperLine Dimensions Fan Model A B C D E F G H FV-10NLF1 13-3/8" 9-1/2" 17-5/16" 7-7/8" 12-5/8" - 22-3/4" 5/16" 4" 11" FV-20NLF1 13-3/8" 9-1/2" 21-5/8" 9-7/16" 12-5/8" - 24-7/16"
Equivalent Duct Length Duct Diameter 3" Duct Sizing Equivalent Duct Length (EDL): The Equivalent Duct Length Table (Figure B) shows you how to calculate the equivalent straight duct length in order to overcome static pressure. The EDL chart helps ensure fan performs as expected under the airflow resistance caused by the listed components. A ventilating fan’s performance is plotted on a graph called a performance curve.
Ventilation Controls Min. Max. Min. Rated Specifications CFMs/Watt Sones Warranty Airflow (0.25 in. w.g.)* Bath Fans -10 to 89 CFM 1.4 2.0 1 year 60% Bath Fans -90 to 130 CFM 2.8 2.0 1 year 70% Bath Fans -140 to 500 CFM 2.8 3.0 1 year 70% In-Line Fans 2.8 N/A 1 year N/A www.energystar.
Installation A practical guide to Panasonic fan installation FIG. C Installation A practical guide to Panasonic fan installation Proper fan installation is necessary to Elbows: Rule number one is to avoid optimize performance. The following elbows and bends whenever possible. points outline installation techniques to However, the fact is that many installations help achieve optimum performance.
Green Building Programs & Green FAQs exhaust fan. is the reciprocal of the run time. If What makes a WhisperGreen fan a Green product? it operates one-third of the time, it The Green concept is a combination must be increased to three times the of energy efficiency, sustainability, continuous rate in the table. The easiest improved interior environment (IAQ), As the required code for California, way to meet the requirements is to and operating cost.
FAQs Frequently Asked Questions 1. What is a sone? Panasonic blower wheel is designed airflow, Panasonic fans will use fewer 6. Why do Panasonic Fans have excessive heat that is a common exhaust and a Panasonic ventilation A sone is an internationally recognized more efficiently than most competitor kilowatt hours and cost less to operate such a long life? problem with recessed light fixtures fan to exhaust the general odors and measurement of sound output.
Notes 50 Notes 51