Dimensions Guide

Filters
WhisperComfort has two air filters. One filter is located on the inside
louver of the grille. The second filter is located in the unit held by a
bracket with a handle. Pull the handle to remove the filter bracket
and remove the filter from the bracket. Both filters should be vacu-
umed with a soft brush attachment.
Exchange Capillary Core
Whisper Comfort's unique core is made from a paper-like mate-
rial and should never be washed or submerged in water. To clean,
vacuum with a soft brush attachment.
VF12485SS - January 2013
Rust-proof paint treatment on galvanized housing
Thermal fuse protection
Meets Washington State Ventilation and Indoor Air Quality
code and ASHRAE 62.2 -2007
3 Year Warranty
Mounting
WhisperComfort measures 14" wide and fits between joists 16" on
center. Adjustable brackets and screws are provided to secure the
unit to the joist on 4 corners.
Wiring
Power consumption is 23 Watts at 40 CFM with a power rating of
120/60 V/Hz. Bring house power to the unit junction box and use 3
wires to connect the 2 switches.
Duct
Insulated 4" duct is recommended. For cold climates, this will help
avoid condensation build up. And for warm climates, this will help
reduce heat transfer to supply air.
In order to reduce unnecessary airflow resistance, duct should be
stretched straight and braced to avoid sagging. Assure that all duct
connections are completely secured with duct tape and/or duct
mastic material.
Termination/Supply Device
The supply device will need to have the back draft damper
removed and replaced with a screen to prevent insects and
small animals from nesting.
The termination and supply devices should be placed a
minimum of 3-feet apart. If placed closer than 3-feet, then the
angle of each device should be mounted at 45-degrees in
opposite directions.
Grille
Follow the Operating Manual to remove the grille from the unit.
Next, remove the filter from the inside louver of the grille. Never use
gasoline, benzene, thinner or any other chemicals when cleaning
the grille or ERV unit. Do not wash grille in a dishwasher which may
cause it to deform. Instead, use light dish soap.
OPTIONAL ACCESSORIES
INSTALLATION
MAINTENANCE (Cleaning)
PRODUCT
Grille
Exchange
Capillary Core
Supply Air Filter
Exhaust Air
Filter
N/A=not applicable
w.g.=water gauge
S.P.=static pressure
Specifications
FV-04VE1
40 CFM 20 CFM 10 CFM
Characteristics
Static pressure in inches w. g. 0.1 0.1 0.1
Air Volume Exhaust (CFM) 40 20 10
Air Volume Supply (CFM) 30 20 10
Noise (sones) 0.8 <0.3 N/A
Power Consumption (Watts) 23 21 17
Speed 1479 1292 1095
Current 0.15 0.10 0.09
Power Rating (V/Hz) 120/60
Specifications
Motor Type Condenser
Type of Motor Bearing Ball
Thermal Fuse Protection Yes
Blower Wheel Type 2 x Sirocco
Apparent Sensible
Effectiveness
Heating (%) 32 °F (0°C) 66% at 30 CFM
Total Recovery
Efficiency
Cooling (%) 95 °F (35°C) 36% at 29 CFM
Note: CFM and sones are tested and certified in accordance
with HVI testing standards. Energy efficiency is tested in
accordance with CSA-C439 standard.
Panasonic WhisperComfort Spot Energy
Recovery Ventilator (ERV) offers a revolutionary
way to provide balanced ventilation. Affordable
and easy to install, WhisperComfort is energy
efficient and provides fresh ventilated air while
maintaining indoor air quality.
FV-04VE1
FV-04VE1
3' (920 mm)
Supply hood
should include
a bird screen
with backdraft
damper removed
Exhaust hood
should include
a backdraft
damper
Alternative Panasonic Solution
SUPPLY
Optional Exterior Wall Cap –
Model # FV-WC04VE1
EXHAUST
Typical Wall Cap Installation
22-1/2 in.
5 in.
10-3/4 in.
3-3/8 in.
5-9/16 in.
8-5/8 in.
8-1/2 in.
4-1/2 in.
20-3/4”
16-3/4”
18-1/2”
13-1/2”
7-7/8”
13-1/2” to 16”
22-1/8”
4”
4”
6-5/8”
13-1/2” to 16”
2 x 4" ducts
FV-04VE1
Optional Exterior Wall Cap Optional Elbow
FV-WC04VE1 FV-EB04VE1
Elbow
Whisper Comfort's FV-EB04VE1
styrofoam elbow accessory con-
nects to the Y shaped adapter
of the exterior wall cap to help
simplify wall installation. The elbow
also features double chambers
for exhaust and supply air to help
prevent cross contamination.
Exterior Wall Cap
Unlike previous installations where two wall caps were
required, WhisperComfort’s FV-WC04VE1 polypropylene
wall cap accessory with styrofoam adaptor conveniently
allows both exhaust (from the right) and supply (from
the left) airow through a 5.5"-5.75" hole in the building
envelope. The dividers inside the bottom portion of the
unique Y shape chamber and the new wall cap help
prevent cross contamination.
To achieve optimum performance and air ow momentum, allow a 2-3 foot
straight run of ex duct out of the unit before the rst 90 degree bend. If you
connect the ERV unit directly to the Y shaped adapter of the exterior wall cap,
you can skip this step.
WhisperComfort
Ventilation Fans
n
Spot balanced ventilation
n
Low-rate continuous run ideal for multi-
family dwellings
n
Ideal for new air tight homes built to
meet energy efficiency standards
n
UL listed for ceiling or wall mount
installation
n
Exchange capillary core recovers heat
energy and moisture
n
Balances air pressure inside the house
Maintenance instructions can be
found in the Operating Manual.
Insulated duct
Tape
Tape
Outdoor
Fig. 11-4
Indoor
Floor
Elbow
(FV-WC04VE1)
Exterior wall
Y-Shaped Adapter
(FV-WC04VE1)
Exterior Wall Cap
(FV-WC04VE1)
0.00
0.10
0.20
0.30
0.40
0.50
0102030405060
Airflow(CFM)
20 Feet
40 Feet
60 Feet
80 Feet
100 Feet
FV-04VE1
(Exhaust)
FV-04VE1
(Supply)
FV-04VE1 40/20 CFM or 20/10 CFM 2 X 4" Ducts
Design and specifications subject to change without notice.
Panasonic Eco Solutions North America
Eco Products Division
One Panasonic Way
Secaucus, NJ 07094
www.panasonic.com/building
For Order Information
PHONE: 866-292-7299
FAX: 888-553-0723
ventfans@us.panasonic.com
Printed with soy ink on 10%
post-consumer recycled paper.

Summary of content (2 pages)