Submittal Sheet

Specification Submittal Data / Panasonic Ventilation Fan
Description
UL listed ceiling or wall mount Energy Recovery
Ventilator provides a tempered air supply,
humidity control, and a balanced amount of
exhaust to help maintain neutral pressure
throughout the home. Panasonic ERV shall
not be installed in a bathroom. Only one unit is
needed for a 1,750 sq. ft. 2 bedroom home to
meet the ASHRAE 62.2 ventilation requirement.
Motor/Blower:
• Fully enclosed AC condenser motor rated for
continuous run.
• Power rating shall be 120 volts and 60 Hz.
• Two highly efcient blower wheels running on
single motor for lower power consumption and
decreased noise.
• Motor equipped with thermal cut-off fuse
control.
Housing:
• Rust proof paint, galvanized steel body.
• Dual 4" intake and exhaust ducts.
• Built in backdraft damper on exhaust duct.
• Filters on supply and exhaust air extend the
life of the ERV core.
• Expandable mounting bracket up to 16” on
center.
Grille:
• Attractive design using ABS material.
• Attaches directly to housing with torsion
springs.
Warranty:
• All Parts: 3 Years from original purchase date.
Architectural Specifications:
ERV shall be ceiling or wall mount type with no
less than 40 CFM on the exhaust port, 30 CFM
on the supply port, and no more than 0.8 sone
as tested in accordance with HVI 915 and 916
standards at 0.1 static pressure in inches water
gauge. Power consumption shall be no greater
than 23 watts. Apparent Sensible Effectiveness
for heating shall be no less than 66% at 30
CFM net air ow under 32°F (0°C) as tested in
accordance with CSA-C439. Total Recovery
Effectiveness for cooling shall be no less than
36% at 29 CFM net air ow under 95°F (35°C).
The supply port damper shall close below 20°F
(-7°C) to prevent freezing of the core. The motor
shall be totally enclosed, AC condenser type
engineered to run continuously. Power rating
shall be 120v/60Hz. Duct diameter shall be no
less than 4". ERV can be used to comply with
ASHRAE 62.2, LEED, IAP, California Title-24,
and WA Ventilation Code.
ERV Core Technology:
• Indoor and outdoor air passes through
Panasonic’s capillary core technology.
This process tempers supply air while
transferring moisture and energy.
• Built in Frost Prevention Mode prevents the
core from freezing. Frost Prevention Mode
is free of interaction and operates without
intervention.
FV-04VE1
Panasonic Eco Solutions North America
Eco Products Division
Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
VF11081SS-04VE1
Specications: WhisperComfort FV-04VE1
Air Volume Setting 40 CFM 20 CFM 10 CFM
Static Pressure in inches w. g. 0.1 0.1 0.1
Exhaust Air Volume (CFM) 40 20 10
Supply Air Volume (CFM) 30 20 10
Noise (sones) 0.8 <0.3 N/A
Power Consumption (watts) 23 21 17
Speed (RPM) 1479 1292 1095
Current (amps) 0.15 0.10 0.09
Power Rating (V/Hz) 120/60
Apparent Sensible Effectiveness for Heating 66% at 30 CFM and 32°F (0°C)
Total Recovery Efciency for Cooling 36% at 29 CFM and 95°F (35°C)
FV-04VE1
Two 4" ducts
Energy Recovery Ventilator
Optional Exterior Wall Cap and Elbow Accessories
(see next page)