PRECAUTIONS FOR PROPER USE
Refer to General precautions, and to the “Operation Guide” on our

Never use this product as a sensing device
for personnel protection.
In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
The FX-100 series does not use the horizontal
connectors that are used with the FX-300 / FX-410
series. Please note that horizontal connection cannot be
performed using a connector attached cable. In addition,
the optical communication function is not equipped on
the FX-100 series, so it is unable to perform interference
prevention for use with the FX-300 / FX-410 series.
If using the FX-100 series together with the FX-300 /
FX-410 series side-by-side, please set the same models
together in groups.
Make sure that the power supply is OFF while adding or

Note that if a voltage exceeding the reted range is applied,
or if an AC power supply is directly connected, the product
may get burnt or damaged.
Note that short-circuit of the load or wrong wiring may burn
or damage the product.
Do not run the wires together with high-voltage lines or
power lines, or put them in the same raceway. This can
cause malfunction due to induction.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power
supply is connected to an actual ground.
In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this product,
connect the frame ground (F.G.) terminal of the equipment
to an actual ground.
Make sure to use the quick-connection cable (optional) for
the connection of the controller.
Extension up to total 100 m
328.084 ft is possible with 0.3
mm
2
or more, cable. However, in order to reduce noise,
make the wiring as short as possible.




1
Fit the rear part of the mounting

1.378 in width DIN rail.
2
Press down the rear part of the
mounting section of the unit on the
35 mm
1.378 in width DIN rail and

section to the DIN rail.



Setting mode appears after the MODE key is pressed for
2 sec. in RUN mode.
Setting item
Factory setting
Description
Teaching
mode
Threshold value can be set in 2-point teaching,
limit teaching, or full-auto teaching.
Output
operation
setting

Light-ON or Dark-ON can be set.
Timer
operation
setting

Without timer, ON delay timer, or OFF delay
timer can be set.
Timer
setting


In case of setting ON-delay timer or OFF-delay
timer in the timer operation setting mode, timer
can be set. When timer is not set, this mode is
not displayed.
Emission
amount
setting
Level 3
Setting for reduced intensity of emission
amount is possible when the incident light
intensity is saturated.
Emission
frequency
setting

0 (Response time:
250 µs or less)

1 (Response time:
2.5 ms or less)

interference can be prevented by setting
different emission frequency. However, when
emission frequency 0 is set, interference
cannot be prevented. Response time
corresponds to emission frequency.
Operation indicator
(Orange)
MODE key
ON key /
Setting value UP key
OFF key /
Setting value DOWN key
Digital display (Green)
(Threshold value)
Digital display (Red)
(Incident light intensity)
35 mm 1.378 in width DIN rail
1
2

1

2
Lift up the front part of the


forward, the hook on the rear portion of the mounting section is likely
to break.

Use M3 screws with washers
for mounting. The tightening
torque should be 0.5 N·m or
less.
1
2
M3 screw
with washer