Datasheet

173
Digital Fiber Sensor FX-100 SERIES
Selection
Guide
Fibers

FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS

PRO mode appears after the MODE key is pressed for 4
sec. in RUN mode.
Setting item
Factory setting
Description
Shift
setting



to set the present incident light intensity as a
threshold value.
External
input
setting

External input can be selected from emission

teaching, ECO (Note 1), 2-point teaching or
emission amount test. When setting the incident
light intensity test “
”, output turns ON /
OFF every 100ms when the rate of incident
light intensity and threshold value is less than
half of the set shift amount (for example, when
the rate of incident light intensity and threshold

at external input.
Threshold
value-storing
setting mode
(Note 2)

Threshold value set at the limit teaching,
full-auto teaching or 2-point teaching by
external input is stored. When selecting
Auto in the emission amount setting
mode, the set emission amount level is
also stored.
Threshold
value
follow-up
cycle
setting
(Note 3)

When incident light intensity exceeds threshold
value, this mode can change the threshold value
with each set cycle depending on variations of the
incident light intensity. The follow-up shift amount
is same as the one set in the shift setting mode.
However, the threshold value is not stored.
GETA
function
setting
(Note 4, 5)

Variations can be reduced by correcting the

to a target value. Target value to offset incident
light intensity can be selected from 0 to 2,000
by 100 unit each. For example, if the target
value is set to 2,000 when the incident light
intensity is 1,500, the incident light intensity
becomes 2,000.
ECO
setting

It is possible to light up / turn off the digital
display. When ECO setting mode is ON, the
display turns off in 20 sec. approx. in RUN
mode. To light up the display again, press any
key for 2 sec. or more.
Digital display
inversion
setting

Digital display can be inverted.
Threshold
value
margin
setting

Margin for threshold value to the present
incident light intensity can be checked. When
there is no margin, it is possible to make the
digital display blink.
: Set to “OFF”: does not function
.
:
Green blinks
.
:
Red blinks
.
:
Red and green blink
.
:
When conducting limit teaching or 2-point
teaching by external input, in case the rate of reference
incident light intensity and threshold value after teaching

amount, output turns ON / OFF every 100 ms. (Note 6)
Setting
copy



For details, refer to “
”.
Reset

Returns to default settings (factory settings.)



Refer to the copy unit SC-SU1 for details.
Be sure to use the setting copy function between the
identical models (Between  models or 
models).
This function cannot be used between different
models.
Only one sensor can be connected on slave side with a
master side sensor for the setting copy function.
Threshold value, output operation setting, timer
operation setting, timer setting, light-emitting amount
setting, shift setting, external input setting, threshold
value margin setting, ECO setting, digital display
inversion setting, and threshold value margin setting
can be copied.

1

“Copy sending ON”, and press the MODE key so that
” is shown on the digital display and the
sensor is in copy ready state. For the setting method,
refer to “Operation guide”.
2

3


4


5
” is shown on the green digital display of the master

digital display of it, then the copying starts. During copy
communication, “
” is shown on the green digital

communication indicator (“




   ”) is displayed on
the red digital display.
6
When the copying is completed, “ ” is shown on the


is shown on the red digital display of it.
7


* 
3
to
7
.
Note: Take care that if the power is not turned on at the same time, the
setting contents may not be copied.

1


2
Press the MODE key for 2 sec. approx.
Master side amplifier
Slave side amplifier
Color code of cable with connector
+
12 to 24V DC
±10 %
(Brown) +V
(Black) Input
(White) External input
(Blue) 0 V
(Brown) +V
(Black) Input
(White) External input
(Blue) 0 V
PRECAUTIONS FOR PROPER USE
Refer to General precautions, and to the “Operation Guide” on our

Notes: 1) When ECO is selected at the external input setting mode, key
operation on the main body is invalid during external input.
2) This mode is not indicated unless any of “
”, “ ”,
” or “ ” is set at the external input setting mode.
3)
If the incident light intensity becomes “300” or less, the follow-up
operation stops. In that condition, threshold value [digital display


is applied, the function cannot be used depending on use conditions.
4) If MODE key is pressed in RUN mode when GETA function is
used, the incident light intensity before setting GETA function is
displayed on the red digital display for 2 sec. approx.
5) When GETA function is used in saturation of incident light intensity
(4,000 or more,) “
” is indicated on the red digital display.
Correction value is up to 4,000.
6)
This mode does not operate unless any of “ ”, “ ” or
” is set at the external input setting mode.
03/01/2012