The code setting function makes it possible to set the
output operation, timer operation, amount of light emitted,
frequency of light emitted, ECO setting, external input,
and amount of shift by selecting a code of one’s choice.
While in the RUN Mode, pressing and holding both
the ON key (
) and OFF key ( ) simultaneously for 4
seconds will switch to the code setting function.

The quick setting function makes it possible to set
the content of the SET Mode (output operation, timer
operation, amount of light emitted, and frequency of light
emitted) simply by selecting a setting number.
While in the RUN Mode, pressing and holding both
the ON key (
) and OFF key ( ) simultaneously for 2
seconds will switch to the quick setting function.

No.
Output operation
Timer
Emission amount setting
D-ON non Level 3 (OFF)
D-ON non Level 2 (ON)
D-ON ofd 10 ms Level 3 (OFF)
D-ON ofd 10 ms Level 2 (ON)
D-ON ofd 40 ms Level 3 (OFF)
D-ON ofd 40 ms Level 2 (ON)
D-ON ond 10 ms Level 3 (OFF)
D-ON ond 10 ms Level 2 (ON)
D-ON ond 40 ms Level 3 (OFF)
D-ON ond 40 ms Level 2 (ON)
L-ON ond 40 ms Level 2 (ON)
L-ON ond 40 ms Level 3 (OFF)
L-ON ond 10 ms Level 2 (ON)
L-ON ond 10 ms Level 3 (OFF)
L-ON ofd 40 ms Level 2 (ON)
L-ON ofd 40 ms Level 3 (OFF)
L-ON ofd 10 ms Level 2 (ON)
L-ON ofd 10 ms Level 3 (OFF)
L-ON non Level 2 (ON)
L-ON non Level 3 (OFF)

Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
Never disassemble or modify this product.
EEPROM is adopted to this product. It is not possible to
conduct teaching 100 thousand times or more, because
of the EEPROM’s lifetime.
Take care that the product is not directly exposed

frequency lighting device or sunlight etc., as it may affect
the sensing performance.
This product is suitable for indoor use only.
Avoid dust, dirt, and steam.
Take care that the product does not come in contact with
oil, grease, organic solvents, such as thinner, etc., strong
acid or alkaline.
This product cannot be used in an environment

PRECAUTIONS FOR PROPER USE

Notes: 1) When the present setting is out of the code setting range, “ ” is shown.
When “
” is selected, the set content of the digit is not changed.
2) The factory setting is “
”.
Refer to General precautions, and to the “Operation Guide” on our

Code
1st digit 2nd digit 3rd digit
4th digit
Output
operation
Timer
(Note 1)
Emission
amount
setting
Emission
frequency
ECO
External
input
Shift
(Note 1)
FX-101
FX-102
D-ON
non
Level 3
(OFF)
01
OFF
Emission
halt

ond 10 ms
12
Limit


ond 40 ms
23
Limit


ofd 10 ms
34
Full-auto
teaching

ofd 40 ms
Level 2
(ON)
01
ECO 
L-ON
non
12
ON
Emission
halt

ond 10 ms
23
Limit


ond 40 ms
34
Limit


ofd 10 ms
Level 1
01
Full-auto
teaching

ofd 40 ms
12
ECO 
23
OFF
2-point
teaching
34
Incident light
intensity test
Auto
01
ON
2-point
teaching
12
Incident light
intensity test
23
34