Datasheet

Digital Fiber Sensor FX-100 SERIES
158
Selection
Guide
Fibers

FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN MACHINE
INTERFACES
ENERGY CONSUMPTION
VISUALIZATION
COMPONENTS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Refer to “” and “
in “
PRECAUTIONS FOR PROPER USE” for details.
 in 
9 mm
0.354 in
[Stable sensing comparison]
Three-chemical
emitting element
FX-100
Light-emitting
amount
Time
Long-term
stability
OFF
ON
OFF
ON
ON
OFF
ON
OFF
Quick setting: Press and simultaneously for 2 sec.
Code setting: Press and simultaneously for 4 sec.
Quick setting numbers (summary)
Output
operation
Timer
Light-emitting
amount selection
No
Dark-ON
Dark-ON
Dark-ON
Dark-ON
Light-ON
Light-ON
Light-ON
Light-ON
None
None
OFF-delay 10 ms
OFF-delay 10 ms
ON-delay 40 ms
ON-delay 40 ms
ON-delay 10 ms
ON-delay 10 ms
Very slim at only 9 mm 0.354 in. This is much thinner

when only using one unit, when using many units this
makes a very large difference.
Utilizes the standard Panasonic Electric Works SUNX

element” for light emission. The light emission is
guaranteed to be stable over long periods of time.

We are using the operation system of digital pressure sensor DP-100, which has been highly praised since it went
on sale. We have separated the settings levels into three levels: RUN mode, SET mode, and PRO mode, making
operation simpler and easier.

RUN mode
Simply imputing the default setting “Code (number)”
will enable sensor settings. Even if the settings are
accidentally changed, imputing the code will restore the
default settings.

by simply quoting numbers. This can be of great
assistance when dealing with foreign country customers.
RUN mode
SET mode
PRO mode
. Changing threshold values . Key lock
. Quick settings . Code settings
. Teaching . L-ON / D-ON setting
. Timer setting . Attenuation function
. Interference prevention function
. Shift . External input . Reset
. GETA . ECO . Display reversing
. Surplus value display . Copy
. Threshold tracking
Simple setting
Special and detailed setting
Functions used during normal operation
Functions used when initializing
the sensor and carrying out maintenance
Equipped with a full complement
of digital fiber sensor functions