Datasheet

165
Digital Fiber Sensor FX-100 SERIES
Selection
Guide
Fibers

FX-500
FX-100
FX-300
FX-410
FX-311
FX-301-F7/
FX-301-F
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
LIST OF FIBERS

Model No.
Sensing range (mm
in) (Note 1) (Note 2)
Type
Fiber cable
length
: Free-cut
Dimensions
Standard type 
Long sensing range type 
FD-FM2S
100 3.937 345 13.583
M6, Sleeve
2 m 6.562 ft
P.101
FD-FM2S4
100 3.937 345 13.583
P.101
FD-G4
50 1.969 120 4.724
M4, High precision P.101
FD-G6
50 1.969 120 4.724
M3, High precision P.102
FD-G6X
45 1.772 160 6.299

1 m 3.281 ft
(Note 3)
P.102
FD-G40
50 1.969 120 4.724
Metal-free
2 m 6.562 ft
P.101
FD-G60
100 3.937 410 16.142
P.102
FD-H13-FM2
100 3.937 280 11.024
Heat-resistant, 130
°C
266
°F
P.102
FD-H18-L31
0 to 10 0.000 to 0.394 0 to 25 0.000 to 0.984
Heat-resistant, 180
°C
356
°F
P.102
FD-H20-21
90 3.543 280 11.024
Heat-resistant,
200 °C
392 °F
M4
1 m
3.281 ft
P.102
FD-H20-M1
120 4.724 300 11.811
M6 P.102
FD-H25-L43
4 to 16 0.157 to 0.630 4 to 23 0.157 to 0.906
Heat-resistant,

3 m
9.843 ft
P.103
FD-H25-L45
7 to 35 0.276 to 1.378 7 to 38 0.276 to1.496
P.103
FD-H30-KZ1V-S
(Note
4)
25 to 80 0.984 to 3.150 10 to 220 0.394 to 8.661
Vacuum-resistant,
Heat-resistant
1 m
3.281 ft P.103
FD-H30-L32
2 to 9 0.079 to 0.354 0 to 17 0.000 to 0.669
Heat-resistant, 300
°C
572
°F
2 m 6.562 ft P.103
FD-H30-L32V-S
(Note 4)
2.5 to 6.5 0.098 to 0.256 0 to 11 0.000 to 0.433
Vacuum-resistant,

3 m
9.843 ft P.103
FD-H35-20S
85 3.346 200 7.874
M4, Sleeve
1 m 3.281 ft P.104
FD-H35-M2
75 2.953 280 11.024
Heat-resistant, 350
°C
662
°F
2 m 6.562 ft
P.104
FD-H35-M2S6
75 2.953 280 11.024
M6, Sleeve
P.104
FD-HF40Y
ø4 mm ø0.157 in
Protective tube: Fluorine resin, length 500 mm 19.685 in (cuttable)
Liquid surface not contacted: Beam received,
Liquid surface contacted: Beam interrupted
Liquid/Liquid leak
sensing
2 m 6.562 ft
P.104
FD-L4
5 to 8 0.197 to 0.315
(Convergent point 6 0.236)
1 to 17
0.039 to 0.669
(Convergent point 6 0.236)

P.104
FD-L41
3 to 14 0.118 to 0.551
(Convergent point 8 0.315)
1.5 to 16
0.059 to 0.630
(Convergent point 8 0.315)
P.104
FD-L43
0 to 19 0.000 to 0.748 0 to 25 0.000 to 0.984
P.104
FD-L44
0 to 6 0.000 to 0.236 0 to 8 0.000 to 0.315
P.104
FD-L44S
0 to 4.5 0.000 to 0.177 0 to 5.5 0.000 to 0.217
P.104
FD-L45
0 to 40 0.000 to 1.575 0 to 50 0.000 to 1.969
3 m 9.843 ft
P.104
FD-L45A
10 to 33 0.394 to 1.299 (Note 5)
P.105
FD-L46
16 to 30 0.630 to 1.181 12 to 50 0.472 to 1.969
4 m 13.124 ft P.105
FD-L47
28 1.102 30 1.181
3 m 9.843 ft P.105
FD-NFM2
35 1.378 100 3.937
M4
2 m 6.562 ft
P.105
FD-NFM2S
35 1.378 100 3.937
M4, Sleeve
P.105
FD-NFM2S4
35 1.378 100 3.937
P.105
FD-P2
25 0.984 65 2.559
ø1.5 mm ø0.059 in, Flexible
1 m 3.281 ft P.105
FD-P40
8 0.315 30 1.181
M3, Flexible
2 m 6.562 ft
P.105
FD-P50
45 1.772 150 5.906
ø3 mm ø0.118 in, Flexible
P.105
FD-P60
45 1.772 150 5.906
M4, Flexible P.105
FD-P80
90 3.543 200 7.874
M6, Flexible P.105
FD-P81X
70 2.756 220 8.661

1 m 3.281 ft P.106
FD-R80
70 2.756 180 7.087
M6, Elbow 2 m 6.562 ft P.106
FD-S30
45 1.772 155 6.102
Super quality,
ø
3 mm
ø
0.118 in,
Flexible
2 m 6.562 ft P.106
FD-S31
35 1.378 140 5.512
ø
3 mm
ø
0.118 in,
Flexible
2 m 6.562 ft P.106

2) 
3) The allowable cutting range is 700 mm
27.559 in
FV-BR1FT-J8).
5) The sensing range is changed due to tilt of senseing object.

03/01/2012