Before attempting to connect or operate this product, please read these instructions completely.
ENGLISH VERSION The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
PREFACE ....................................................... 2 FEATURES ..................................................... 2 PRECAUTIONS .............................................. 3 MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS ........................................ 5 PREPARATIONS ............................................. 8 SYSTEM CONNECTIONS ............................... 9 EXTERNAL SYNCHRONIZATION .................. 10 PREVENTION OF BLOOMING AND SMEAR .. 10 SPECIFICATIONS .................
PREFACE The Panasonic GP-MF130 Machine Vision B/W CCD Camera has a 1/3” Interline Transfer CCD image sensor which features 440 000 pixels, a horizontal resolution of 560 lines, and minimum smear. FEATURES 1. Newly developed multi-function solid state image sensor 1/3” Inter Line Transfer type CCD image sensor with 752 (H) x 582 (V) pixels. 3. External synchronization : External HD/VD input enables system setup with external video processors, etc. 4.
PRECAUTIONS 1. Do not attempt to dissemble the camera. To prevent electric shock, do not remove screws or covers. There are no serviceable parts inside. Ask a qualified service person for servicing. 4. Do not use the strong or abrasive detergents when cleaning the camera body. Use a dry cloth to clean the camera when dirty. In case the dirt is hard to remove, use a mild detergent and wipe gently. 2. Handle the camera with care. Do not abuse the camera. Avoid striking, shaking, etc.
7. Do not drop anything inside the camera. Dropping metal for example inside the camera could permanently damage the unit. If anything is dropped inside the camera, turn the power off immediately and ask a qualified service person for servicing. 8. Do not operate the camera beyond the specified temperature, humidity or power source ratings. Use the camera under conditions where temperature is between −10°C - +50°C (14°F - 122°F), and humidity is below 90 %. The input power source is DC 12 V, 170 mA.
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS !2 !3 !4 130 ON OFF 1 q 6 r e w 12P VIDEO t ON OFF 1. 1/3” Manual Iris Lens (Sold Separately) 1 6 u o !1 y i !0 2. Camera Connector (12-pin) This is connected with the optional Camera Cable GP-CA34 , GP-CA33, GP-CA59 or GP-CA60.
q o w !0 i e !1 !2 u r t y Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 CAUTION: CONNECT THIS TO A DC 12V CLASS 2 POWER SUPPLY ONLY. 4. Manual Gain Control This controls the gain level from 0 to 6 dB. 5. Video Output Connector This connector is used to connect with the VIDEO IN connector of the monitor. ON 6. Switch 1 No.1 (1/ON) 1 This switch selects the Field or Frame Accumulation.
The shutter speed can be set as below: Switch 1 No. 2 No. 3 No. 4 No. 5 OFF OFF OFF OFF ON OFF OFF OFF Shutter Speed 1/120 ON OFF OFF 1/500 ON ON OFF OFF 1/1 000 OFF OFF ON OFF 1/2 000 ON ON OFF 1/4 000 OFF ON ON OFF 1/8 000 ON ON ON OFF 1/16 000 OFF OFF OFF ON 1/32 000 ON OFF OFF ON 1/64 000 OFF ON ON OFF Other Combinations 12. Switch 2 No.1 (1/ON) 1 ON Switch 2 No.2 (2/ON) 2 ON Switch 2 No.3 (3/ON) 3 ON Normal OFF OFF ON 11. Switch 1 No.
PREPARATIONS 1. Power Supply for Camera 3. Switch Covers Removal Prepare a regulated DC power supply which can supply DC 12 V ±10 % 170 mA or more current and rated CLASS 2. Caution: The following preparation should be made by qualified service personnel or system installers. For setting the Switch 1 No.1 to 6 and 2 No. 1 to 6, remove the switch cover fixing screw on the side panel as shown below. 2. Lenses Be sure to use the optional manual iris lens having the following items.
SYSTEM CONNECTIONS Caution: Keep the power switches of all units to OFF before connections. 1. Connect the optional camera cable GP-CA34 between the connector of this camera and the 12 V DC Class 2 power supply(not provided as an accessory). 2. Connect the video connector of the GP-CA34 to the Video Monitor.
EXTERNAL SYNCHRONIZATION Note: If the picture appears disturbed, be sure to match the phases of falling edges of the external HD/VD. 2 : 1 Interlace The GP-MF130 works in 2 : 1 interlace mode when external 2 : 1 interlaced HD/VD signal is supplied to pin-6 and pin-7 of the camera connector (12-pin). PREVENTION OF BLOOMING AND SMEAR , , , , , , When the camera is aimed at a bright light, such as a spotlight, or a surface that reflects bright light, smear or blooming may appear.
SPECIFICATIONS Pick-up Device : Image Size : Synchronization : External Reset : Horizontal Resolution : Minimum Illumination : Signal to Noise Ratio: Gamma : Gain Selection : Electronic Shutter : Lens Mount : Inter Line Transfer type CCD with 752 (H) x 582 (V) pixels. 1/3” (6.00 (H) x 4.96 (V) mm) 2 : 1 interlace 1-line interlace (Frame accumulation) 2 : 1 interlace 2-line interlace (Field accumulation) Internal or External (Selectable Automatically) Internal : Built-in sync generator External : 4.
Vibration Resistance : Shock Resistance : Power Source : Ambient Temperature : Dimensions : Weight : 10 G (10 Hz - 150 Hz) (2 hours each for three axes) 80 G (IEC 68) *IEC=International Electronical Technical Commission DC + 12 V, 170 mA −10˚C - +50˚C (14˚F - 122˚F) 29(W) x 29(H) x 65(D) mm [1-1/8”(W) x 1-1/8”(H) x 2-13/16”(D)] 86 g (0.19 lbs.) (Camera Only) Dimensions and weight indicated are approximate values. Specifications are subject to change without notice.