Datasheet

Rectangular-shaped Inductive Proximity Sensor GX-F/H SERIES
768
Selection
Guide
Amplier
Built-in
Amplier-
separated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Notes: 1) Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +23 °C +73 °F.
2) “ I ” in the model No. indicates a different frequency type.
3) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage uctuation.
4) Panasonic Electric Works SUNX’s IP68 test method
1
Immerse at 0 m below 0 °C +32 °F water surface and leave for 30 min. Then, immerse at 0 m below +70 °C +158 °F water surface and leave for 30 min.
2
Regard the heat shock test in
1
as one cycle and perform 20 cycles.
3
Leave in water at a depth of 1 m 3.281 ft in water for 500 hours.
4
After tests
1
to
3
, insulation resistance, voltage withstandability, current consumption, and sensing ranges must meet the standard values.
5) If using the sensor in an environment where cutting oil droplets splatter, the sensor may deteriorate due to added substances in the oil.
SPECIFICATIONS
GX-12 type
Type NPN output PNP output
Model No.
(Note 2)
Front sensing
GX-F12A(I) GX-F12B(I) GX-F12A(I)-P GX-F12B(I)-P
Item Top sensing GX-H12A(I) GX-H12B(I) GX-H12A(I)-P GX-H12B(I)-P
Max. operation distance (Note 3)
4.0 mm 0.157 in ± 8 %
Stable sensing range (Note 3) 0 to 3.3 mm 0 to 0.130 in
Standard sensing object Iron sheet 20 × 20 × t 1 mm 0.787 × 0.787 × t 0.039 in
Hysteresis 20 % or less of operation distance (with standard sensing object)
Repeatability Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less
Supply voltage
12 to 24 V DC
+10
–15
% Ripple P-P 10 % or less
Current consumption 15 mA or less
Output
NPN open-collector transistor
• Maximum sink current: 100 mA
Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 2 V or less (at 100 mA sink current)
PNP open-collector transistor
• Maximum source current: 100 mA
Applied voltage: 30 V DC or less (between output and +V)
• Residual voltage: 2 V or less (at 100 mA source current)
Utilization category DC-12 or DC-13
Output operation Normally open Normally closed Normally open Normally closed
Max. response frequency 500 Hz
Operation indicator Orange LED (lights up when the output is ON)
Environmental resistance
Pollution degree 3 (Industrial environment)
Protection IP68 (IEC), IP68g (JEM) (Note 4, 5)
Ambient temperature –25 to +70 °C –13 to +158 °F, Storage: – 40 to +85 °C 40 to +185 °F
Ambient humidity 35 to 85 % RH, Storage: 35 to 95 % RH
EMC EN 60947-5-2
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 500 Hz frequency, 3 mm 0.118 in amplitude (Max. 20 G) in X, Y and Z directions for two hours each
Shock resistance 10,000 m/s
2
acceleration (1,000 G approx.) in X, Y and Z directions for three times each
Sensing
range
variation
Temperature characteristics
Over ambient temperature range –25 to +70 °C –13 to +158 °F: Within ±8 % of sensing range at +23 °C +73 °F
Voltage characteristics
Within ±2 % for
+10
–15
% uctuation of the supply voltage
Material Enclosure: PBT, Indicator part: Polyester
Cable 0.15 mm
2
3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long
Cable extension Extension up to total 100 m 328.084 ft is possible with 0.3 mm
2
, or more, cable.
Net weight Front sensing type: 20 g approx., Top sensing type: 20 g approx..