Datasheet

HE
1
ds_61C06_en_he: 100811D
CLASSIFICATION
PRE-TENSION AND KICK-OFF MECHANISM
TV-15, 30 AMP (1 Form A)
Power Relay
HE RELAYS
Type PC board Plug-in TM Screw terminal
Operating funciton Single side stable
Contact arrangement 1 Form A 1 Form A 2 Form A 1 Form A 2 Form A 1 Form A 2 Form A
VDE
1 Form A Plug-in type
Form A type also available with
48A contact capacity
Refer to data sheet, starting on page 9.
FEATURES
1. Excellent resistance to contact
welding
Owing to the pre-tension and kick-off
mechanism, the 1 Form A passes TV-15
and the 2 Form A passes TV-10.
2. High-capacity and long life
3. Excellent surge resistance
Between contacts and coil, the surge
voltage is more than 10,000 V
(when surge waveform accords with
JEC-212-1981).
4. Compatible with all major safety
standards
UL, CSA, VDE and TÜV certified
TYPICAL APPLICATIONS
1. Office equipment
Copiers, package air conditioners,
automatic vending machines.
2. Industrial equipment
Machine tools, molding equipment,
wrapping machines, food processing
equipment, etc.
3. Home appliances
Air conditioners, microwave ovens,
televisions, stereo systems, water
heaters and air heating equipment.
Contact
arrangement
1 Form A type 2 Form A type
Contact capacity 30A 20A
Electrical life
(at 20 cpm)
210
5
Mechanical life
(at 180 cpm)
DC type: 10
7
, AC type: 510
6
Type
Single side stable type
HE 1 Form A, 2 Form A
Insulation gap Min. 8 mm
Distance between contacts*
1 Form A and 2 Form A:
Min. 3 mm
PC board type:
Min. 2.5 mm
Breakdown
voltage
Between open contacts 2, 000 Vrms for 1 min.
Between contact and coil 5, 000 Vrms for 1 min.
Kick-off
Gap
Moving plate
At return
1
.
P
re-
t
ens
i
on mec
h
an
i
sm
Before operation, the moving
spring is pre-tensioned by
being held down by a moving
plate. As a result, at the ON
moment, with little follow,
contact pressure is ensured
with low bounce.
2
.
Ki
c
k
-o
ff
mec
h
an
i
sm
Even when contact welding
has occurred, at the moment of
return, the moving plate taps
the moving spring (kick-off)
and, in effect, works to tear the
weld apart, thus improving
resistance to welding.
1 Form A 2 Form A
Electrical life
30 A 277 V AC, 10
5
30 A 250 V AC, 20
5
25 A 277 V AC, 10
5
20 A 250 V AC, 20
5
TV rating TV-15 TV-10
Pre-tension
Moving plate
At operation
Contact follow stroke
Direction of operation
Contact pressure
0
HE relay
(with pre-tension)
Ordinary relay
(without pre-tension)

Summary of content (14 pages)