Datasheet

HE
10
ds_61C06_en_he: 100811D
RATING
1. Coil data
2. Specifications
Notes:
*1.This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2.Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3.Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage.
*4.The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to usage, transport and storage
conditions in NOTES on page 12.
*5.Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.
Nominal coil
voltage
Pick-up voltage
(at 20C 68F)
(Initial)
Drop-out voltage
(at 20C 68F)
(Initial)
Nominal operating
current
[10%] (at 20C 68F)
Coil resistance
[10%] (at 20C 68F)
Nominal operating
power
Max. applied voltage
(at 20C 68F)
6V DC
70%V or less of
nominal voltage
10%V or more of
nominal voltage
320mA 18.8
1,920mW
110%V of
nominal voltage
9V DC 213mA 42.2
12V DC 160mA 75.0
24V DC 80mA 300.0
Characteristics Item Specifications
Contact
Arrangement 1 Form A
Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Contact material AgNi type
Rating
Nominal switching capacity 48 A 250 V AC (resistive load)
Contact carring power 12,000 VA (resistive load)
Max. switching voltage 250 V AC
Max. switching current 48 A (AC)
Nominal operating power 1,920 mW
Min. switching capacity (Reference value)*
1
100 mA 5 V DC
Electrical
characteristics
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as “Breakdown voltage” section.
Breakdown
voltage (Initial)
Between open contacts 2,000 Vrms for 1 min. (Detection current: 10 mA)
Between contact and coil 5,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*
2
(Between contact and coil)
10,000 V (initial)
Temperature rise
Max. 60C 140F
(By resistive method, contact carrying current: 48A, 100%V of nominal coil voltage at 55C 131F.)
Max. 30C 86F
(By resistive method, contact carrying current: 48A, 60%V of nominal coil voltage at 85C 185F.)
Coil hold voltage*
3
40 to 100%V (Contact carrying current: 48A, at 20C 68F), 50 to 100%V (Contact carrying current:
48A, at 55C 131F), 50 to 60%V (Contact carrying current: 48A, at 85C 185F)
Operate time (at 20C 68F) Max. 30 ms (nominal coil voltage, excluding contact bounce time)
Release time (at 20C 68F)*
5
Max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode)
Mechanical
characteristics
Shock
resistance
Functional Min. 98 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10 s.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration
resistance
Functional 10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 s.)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life
Mechanical Min. 10
6
(at 180 cpm)
Electrical
Resistive load Min. 310
4
(48 A 250 V AC) (ON : OFF = 1s : 9s)
Inductive load
Endurance: 48 A 250 V AC (cos = 0.8), Min. 310
4
(ON : OFF = 0.1s : 10s)
Overload: 72 A 250 V AC (cos = 0.8), Min. 50 (ON : OFF = 0.1s : 10s)
Conditions
Conditions for operation, transport and
storage*
4
Ambient temperature:
–50 to +55C –58 to +131F (When nominal coil voltage applied)
–50 to +85C –58 to +185F (When applied coil hold voltage is 50% to 60% of nominal coil voltage)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature);
Atmospheric pressure: 86 to 106 kPa
Max. operating speed 6 cpm (at nominal switching capacity ON : OFF = 1s : 9s)
Unit weight Approx. 80 g 2.82 oz