Datasheet

HE
14
ds_61C06_en_he: 100811D
MOUNTING METHOD
NOTES
1. Relay mounting 2. Installing to a DIN rail 3. Removing from a DIN rail
Push
Flat-head screwdriver
1. Be careful not to drop the relay. It is
made of heat-hardened resin and may
break.
2. Be sure to tighten the screw-down
terminals firmly. Loose terminals may
lead to the generation of heat.
3. When the 1 Form A is used in
situations covered by the Japanese
Electrical Appliance and Material
Control Law, the use of 5.5 mm
2
cabling and 30 A current is not
allowed. Consequently, the circuit
should be less than 20 A.
4. When fixing the terminal socket with
screws, to avoid torque damage and
distortion, apply torque within the
ranges shown below.
M3.5 screws:
0.784 to 0.98 N·m (8 to 10 kgf·cm)
M4 screws:
1.176 to 1.37 N·m (12 to 14 kgf·cm)