Datasheet

HE
8
ds_61C06_en_he: 100811D
SAFETY STANDARDS
NOTES
For Cautions for Use, see Relay Technical Information.
Item
UL/C-UL (Recognized) CSA (Certified) VDE (Certified) TV rating (UL/CSA) TÜV (Certified)
File No. Contact rating File No. Contact rating File No. Contact rating File No. Rating File No. Rating
1 Form A
E43028 30A 277V AC
30A 30V DC
1.5HP 125V AC
3HP 250V AC
LR26550
etc.
30A 277V AC
30A 30V DC
1.5HP 125V AC
3HP 250V AC
4000668
1
30A 250V AC (cos=1.0)
30A 250V AC (cos=0.4)
5A 110V DC (0ms)
UL
E43028
TV-15
B 09 04
13461
261
30A 250V AC (cos=1.0)
30A 250V AC (cos=0.4)
8A 110V DC (0ms)
2 Form A
E43028 25A 277V AC
25A 30V DC
1HP 125V AC
2HP 250V AC
LR26550
etc.
25A 277V AC
25A 30V DC
1HP 125V AC
2HP 250V AC
4000668
1
25A 250V AC (cos=1.0)
25A 250V AC (cos=0.4)
5A 110V DC (0ms)
UL
E43028
TV-10
B 09 04
13461
261
25A 250V AC (cos=1.0)
25A 250V AC (cos=0.4)
8A 110V DC (0ms)
1. The dust cover should not be removed
since doing so may alter the
characteristics.
2. Avoid use under severe environmental
conditions, such as high humidity,
organic gas or in dust, oily locations and
locations subjected to extremely frequent
shock or vibrations.
3. When mounting, use spring washers.
Optimum fastening torque ranges from
49 to 68.6 Nm (5 to 7 kgf·cm).
4. Firmly insert the receptacles so that
there is no slack or looseness. To
remove a receptacle, 19.6 to 39.2 N (2 to
4 kg) of pulling strength is required. Do
not remove more than one receptacle at
one time. Always remove one receptacle
at a time and pull it straight outwards.
5. When using the AC type, the operate
time due to the in-rush phase is 20 ms or
more. Therefore, it is necessary for you
to verify the characteristics for your actual
circuit.
6. When using the push-on blocks for the
screw terminal type, use crimped
terminals and tighten the screw-down
terminals to the torque below.
M4.5 screw:
147 to 166.6 Ncm (15 to 17 kgf·cm)
M4 screw:
117.6 to 137 N·cm (12 to 14 kgf·cm)
M3.5 screw:
78.4 to 98 N·cm (8 to 10 kgf·cm)